Product description:

The KaVo IXS is a high-precision sensor designed for use in dental applications. It enables accurate and reliable data acquisition during various procedures. The sensor is characterized by its robust construction and compatibility with a wide range of dental systems. It supports seamless integration into existing workflows and provides clear and precise measurement results. Its compact design facilitates easy handling and ensures optimal performance in clinical environments.

Frequently Asked Questions

How do I assemble the KaVo IXS sensor system?

Assemble the rings, bars, and holders so that the entire sensor area is visible through the ring. This applies to horizontal or vertical Bitewing holders, Periapical (anterior or posterior) holders, and hand-held holders.

What should I do before using the sensor?

Apply a new disposable sheath prior to use to ensure hygiene and reduce the risk of exposure to nickel, which may cause allergic reactions or even cancer.

How should I position the sensor in the patient's mouth?

Carefully follow setup, assembly, and alignment procedures to ensure quality image capture. Position the sensor so that it is parallel to the tooth, and use the paralleling technique for maximum image quality.

What is the correct way to connect the KaVo IXS to the computer?

Verify connectivity of the KaVo IXS to the computer and ensure the green driver icon is displayed before attempting to take an X-ray. This ensures proper communication between the device and the system.

What should I do if the patient moves during exposure?

For maximum image quality, make sure the patient remains still during the exposure. Movement can lead to blurred images and may require retakes, increasing radiation exposure.

How do I safely remove the sensor after exposure?

Carefully remove the sensor from the oral cavity following the exposure. Grasp the sensor and Positioning System and remove the sensor from under the retaining clips to avoid damaging the cable.

What should I do if the sensor cable is damaged?

If the cable is damaged, stop using the device immediately and report the incident to KaVo Customer Support. Damaged cables can lead to sensor malfunction and potential safety risks.

How can I help a child cooperate during sensor placement?

Prepare the child both physically and psychologically by using diversion techniques. Have them focus on the end result, such as seeing an instant image of their teeth. Let them hold the sensor without biting it to get used to its feel.

How can I protect the sensor cable during positioning?

Place the sensor cable into the groove on the holder and use the Aiming Bar Cable Clips for protection. Ensure the cable is adjacent to the holder and not between the holder and the teeth to prevent crimping when the patient closes their mouth.