Log in


or


google Continue with Google facebook Continue with Facebook

Already have an account?

Sentiotec PRONET (124 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

Product description:

The Server Sentiotec PRONET is a high-performance server designed for reliable data processing and storage. It features a robust hardware configuration, scalable architecture, and efficient cooling systems to ensure stable operation under heavy workloads. The server supports a wide range of network protocols and is optimized for use in professional environments such as data centers and enterprise networks. Its modular design allows for easy expansion and maintenance, making it a versatile solution for various IT applications.

Frequently Asked Questions

How do I connect the Webserver to a new local WLAN network?

To set up a new local WLAN network, use a standard WLAN router with an Ethernet port. Connect the Webserver directly to the router, which will register it as a network participant with a specific IP address. The default IP address is 192.168.0.110. Open your browser and enter this IP address to access the login screen. Use the default username 'sauna' and password 'sentiotec'.

What are the safety precautions for using the Webserver?

Always ensure the power is off before performing any installation or connection work. Do not use the device if under the influence of alcohol, medication, or drugs. Keep flammable objects away from the sauna heater before turning it on. Children under 14 should not operate the device without supervision. The device should not be used by children under 8 years old.

What is the maximum number of sauna controls that can be connected to the Webserver?

The Webserver can be connected to up to 2 sauna controls. It supports compatible models such as Pro B2, Pro B3, Pro C2, and Pro C3. Ensure the firmware of the sauna controls is at least version V1.03 for proper functionality.

How do I verify the connection between the Webserver and the sauna control?

After a successful connection, the transmit and receive indicator lights on the Webserver will blink rapidly, indicating data is being sent and received. If the lights do not blink, check that the sauna control is powered on, the Webserver is receiving power, the cables are properly connected, and the sauna control firmware is at least version V1.03.

What are the technical specifications of the Webserver?

The Webserver is designed to control sauna functions via devices like PCs, smartphones, and tablets. It supports both local networks (LAN, WLAN) and internet access (WEB). It includes a 5 VDC power input, Ethernet connectivity, and a Mini-USB port. The device is compatible with specific sauna control models and requires firmware version V1.03 or higher for optimal performance.

How do I connect the Webserver to an existing LAN network?

To connect the Webserver to an existing LAN network, use an Ethernet cable to link the Webserver to your LAN router. Ensure the router is configured correctly and the Webserver is powered. Once connected, the transmit and receive indicator lights will blink, confirming the connection is active and data is being transmitted.

What should I do if I cannot access the Webserver via the browser?

If you cannot access the Webserver, first verify that the device is powered on and connected to the network. Ensure the IP address is correct and the firmware is up to date. If the issue persists, check the router settings and ensure the Webserver is properly connected to the network. If necessary, reset the Webserver and try again.

What are the compatible sauna control models for the Webserver?

The Webserver is compatible with the following sauna control models: Pro B2, Pro B3, Pro C2, and Pro C3. These models must have firmware version V1.03 or higher for full functionality. Ensure the sauna control is properly connected and configured before attempting to access it via the Webserver.

How do I set up the Webserver for internet access?

To enable internet access, connect the Webserver to your router using an Ethernet cable. Ensure the router is configured to allow internet access and the Webserver is receiving power. Once connected, the Webserver can be accessed remotely via the internet using the assigned IP address or domain name.

What should I do if the Webserver is not responding to commands?

If the Webserver is not responding, check that the device is powered on and properly connected to the network. Ensure the firmware is up to date and the sauna control is also functioning correctly. If the issue persists, restart both the Webserver and the sauna control. If the problem continues, contact the manufacturer for further assistance.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5