HBM WE2111 (152 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do you zero the scale?
To zero the scale, send the command 'z' for a short press or 'Z' for a long press. This will reset the current weight reading to zero.
What is the purpose of the 'P' command?
The 'P' command triggers the transmission of the current weight using the format set in the (Type.A) item of the (SERIAL) group. It is used to request weight readings on serial port 2.
How does the WE2111 respond to commands?
The WE2111 responds with '0crlf' to indicate a command was accepted or '?crlf' if the command was not understood or could not be performed. The Sxx command and RES command do not have a response.
What are the termination characters for commands?
Permissible termination characters include ';', 'LF', 'crlf', and 'LFCR'. The WE2111 always uses 'crlf' as the termination for its responses.
How do you select a specific unit for communication?
Use the 'Sxx' command to select a specific unit. For example, 'S99;' selects all connected indicators. This command should be sent even if only one unit is connected.
What is the function of the 'TDD?' query?
The 'TDD?' query is used to retrieve the current trade counter value. This counter increments based on the weight readings and can be queried for monitoring purposes.
How does the WE2111 handle auto-calibration?
The WE2111 performs auto-calibration every second when stationary and every 10 seconds when in motion. During calibration, measurement is temporarily disabled, and the last available readings are sent to maintain continuity.
What are the parameters for auto-calibration?
Auto-calibration has two parameters: one for calibration at standstill and one for calibration in motion. Both parameters can be set to 0 or 1, with 1 being the default. These settings are valid only in INDUSTRIAL mode.
How do you handle decimal point positioning?
The decimal point position can be adjusted using the IAD command. Parameters can be specified with or without commas, and omitting parameters allows for changing only the desired setting without affecting others.
What happens if the trade counter is incremented with the same data?
The WE2111 increments the trade counter regardless of whether the new data is different from the old data. This means that even if the scale is already at full scale, sending IAD1,6000 will still increment the counter.