Product description:

The COMEM DTI is a surveillance system designed for reliable monitoring and data transmission. It features advanced signal processing capabilities and is suitable for use in various security and surveillance applications. The system ensures high performance and stability, making it a dependable solution for critical monitoring tasks.

Frequently Asked Questions

What is the purpose of the DTI and eDTI temperature monitoring unit?

The DTI and eDTI temperature monitoring unit is used in resin or dry type transformers to monitor temperatures continuously. It can also be adapted for use in oil transformers. It uses PT100 temperature probes to generate alarm and trip signals based on temperature thresholds.

What safety precautions should be followed when installing the DTI/eDTI?

Installation must be carried out by qualified personnel following the instruction manual. Ensure the device is used only for its intended application. Avoid unauthorized or improper operations to prevent risks to life, equipment, and property.

How should the PT100 temperature probes be connected?

Follow the wiring diagram in the manual. Ensure the red and white insulated conductors are not reversed. For three-wire PT100 probes, use the third wire for compensation. For two-wire probes, short-circuit the terminals with the red wire. Use shielded cables and separate power wires to reduce noise.

What are the functions of the output relays in the DTI/eDTI?

The ALARM and TRIP relays activate when temperature thresholds are exceeded. The FAULT relay indicates PT100 anomalies or device faults. The FAN relay controls the cooler fan based on set thresholds. During normal operation, contacts 38-39 are open and 39-40 are closed.

How do you enter the programming mode on the DTI/eDTI?

Press the SET button for a few seconds until the SET LED lights up. This enters the programming mode. Use the → and ← keys to navigate and the ENTER key to confirm changes or exit without saving.

What is the HOLD function and how is it configured?

The HOLD function stores alarm conditions that can only be reset manually using the RESET button when temperatures are below the threshold. To enable or disable it, use the ← and → keys. Press ENTER to confirm the selection.

How do you configure the number of active inputs on the DTI/eDTI?

Select between 3 or 4 active inputs using the ← and → keys. If 3 inputs are selected, the T4 display remains off. Confirm the selection with the ENTER key to save the configuration.

How do you set the ventilation control thresholds on the DTI/eDTI?

Program the temperature thresholds for enabling and disabling ventilation. The FAN LED indicates the programming phase. Use the ← and → keys to select the desired temperature values within the specified range and confirm with ENTER.

How do you set the alarm and trip thresholds for each channel?

Start programming from channel 1. Use the ← and → keys to select the temperature values for the alarm and trip thresholds. The alarm threshold must be below the trip threshold. Confirm each setting with the ENTER key.

How do you configure the MODBUS address for the eDTI model?

Use the T1-T2 display to set the MODBUS address and the T3-T4 display to show the ID. Select a number between 1 and 247 using the ← and → keys. Confirm the selection with the ENTER key to save the configuration.