Product description:
Frequently Asked Questions
What safety precautions should be taken when using the Tab-Ex® Pro?
The Tab-Ex® Pro is designed for use in hazardous areas with gaseous and dust atmospheres. It must be used in accordance with ATEX Directive 2014/34/EU, IECEx System, and NEC/CEC codes. Always follow the safety instructions provided in the manual to avoid serious consequences.
What are the radiation exposure limits for the Tab-Ex® Pro?
The Tab-Ex® Pro complies with ICNIRP, IEEE C95.1, FCC OET Bulletin 65, and CENELEC EN62311 limits for exposure to radio frequency (RF) radiation. The FCC ID and CE marking are printed on the device label. The battery must be removed to access this information.
What are the SAR values for the Tab-Ex® Pro in Europe and the USA?
In Europe, the SAR limit is 2.0 W/kg, and the maximum SAR for this model is 1.057 W/kg for body-worn use. In the USA, the SAR limit is 1.6 W/kg, with a maximum SAR of 1.37 W/kg for body-worn use and 1.59 W/kg for simultaneous transmission.
What bands and frequencies does the Tab-Ex® Pro support?
The Tab-Ex® Pro supports EGSM900, DCS1800, WCDMA 900/2100, LTE 1/3/7/8/20/28/38/40, Wi-Fi 2.4 GHz, Bluetooth 2.4 GHz, ANT+ 2.4 GHz, Wi-Fi 5.1-5.7 GHz, Wi-Fi 5.8 GHz, and NFC 13.56 MHz.
How do I insert the SIM card and microSD card into the Tab-Ex® Pro?
To insert the SIM card and microSD card, first remove the Ex-Protective Cover and Rear Cover. Remove the battery, then insert the SIM card and microSD card into their respective slots. Reinsert the battery and reattach the covers to complete the process.
How should I charge the Tab-Ex® Pro tablet computer?
Charging the tablet computer is only allowed outside hazardous areas. The battery is not fully charged upon delivery, so it is recommended to charge it for five hours before first use. The full capacity is reached after 3-4 complete charge/discharge cycles. Always use ecom-approved chargers and never incinerate the battery.
What are the safety precautions for the battery in the Tab-Ex® Pro?
Damaged batteries and chargers should be removed from use and sent to ECOM Instruments GmbH for inspection. Extreme temperatures can affect battery charging, and the device should never be disposed of in a fire. Lithium-ion batteries have a lifespan of about 500 charge cycles, after which they are considered technically defective and should be replaced.
How should I clean and maintain the Tab-Ex® Pro?
Use only a suitable cloth or sponge to clean the device. Avoid solvents or abrasive agents. Inspect the device's functionality and accuracy every two years. Store the device within the permissible temperature range of -20°C to +60°C to ensure proper maintenance.
What should I do with the Tab-Ex® Pro when it is no longer needed?
Old electrical devices should be disposed of in accordance with European Directive 2002/96/EC. Return depleted batteries to designated containers and avoid disposing of them with normal household waste. Lithium batteries should not be burned or exposed to temperatures exceeding 85°C. Always follow local regulations for proper disposal.
What are the warranty and liability terms for the Tab-Ex® Pro?
The warranty follows the General Conditions of Delivery and Payment of ECOM Instruments GmbH, available at www.ecom-ex.com. The warranty can be extended with an optional Service Level Agreement. Always use ECOM-approved accessories to avoid voiding the warranty and ensure proper device performance.