Frequently Asked Questions
How to purge the heater after maintenance?
After maintenance, open the hot water valve on the faucet to activate the heater. Close the faucet to turn it off. Purge the system by repeatedly opening and closing the hot water valve until no air escapes from the pipe, ensuring the heater is free of air.
What is the default hot water temperature?
The default hot water temperature is set to 50°C at the factory. A qualified technician can adjust this temperature between approximately 30°C and 60°C.
How to clean and maintain the heater?
Clean the heater regularly using a damp cloth. Avoid abrasive, solvent, or chlorine-based cleaning agents. Check and clean the flow regulator and shower head periodically. Have the electrical and water-side components inspected every three years by a certified professional.
What should I do if the water remains cold?
If the water remains cold, check if the circuit breaker has tripped. If so, reset it. If the temperature display does not react, the safety pressure switch or temperature switch may have tripped. Clean the outlet valve or replace the filter sieve if it is clogged.
What is the maximum water flow rate?
The maximum water flow rate varies by model. For CDX 6 and CDX 9, it is 4.0 l/min, and for CDX 7 and CDX 11, it is 5.0 l/min. These values are based on a temperature rise of 33 K. Ensure the flow rate is within these limits for optimal performance.
How to install the heater on the wall?
Install the heater on the wall vertically with the water connections at the bottom. Mark the drilling points using the provided template or by aligning the top and bottom markings. Use a 6 mm drill bit and secure with the provided screws and plugs. Ensure the heater is mounted in a frost-free area.
What are the electrical connection requirements?
Electrical connections must be made by a qualified professional. For CDX 6 and CDX 9, use 4 mm² or 6 mm² cables, and for CDX 7 and CDX 11, use 1.5 mm² or 1.0 mm² cables. Connect the heater to the protective earth conductor and ensure the voltage matches the specifications on the nameplate.
How to adjust the temperature setting?
To adjust the temperature, use a qualified technician to modify the setting between 30°C and 60°C. Ensure the temperature is set appropriately for the intended use, such as showering or domestic hot water, and avoid exceeding the maximum flow rate to maintain efficiency.
What is the warranty and service information?
If the heater continues to malfunction, contact the factory service department. Provide the device type label information. Repairs must be performed by certified professionals. If the power cable is damaged, replace it with an original spare part to avoid safety risks.
What are the technical specifications?
The heater has different power ratings depending on the model: CDX 6-U and CDX 9-U have 6.6 kW and 8.8 kW, respectively, while CDX 7-U and CDX 11-U have 6.9 kW and 11 kW. The water flow rates range from 2.0 to 5.0 l/min, and the heater is designed for use with specific water resistance and conductivity values.
Related products from clage
CBX 13
User manual 48 pages
CBX 13
User manual 2 pages
CBX 11
User manual 2 pages
CBX 11
User manual 48 pages
DBX21 BASITRONIC
User manual 8 pages
DBX21 BASITRONIC
User manual 12 pages
DBX21 BASITRONIC
User manual 20 pages
DBX21 BASITRONIC
User manual 20 pages
DBX21 BASITRONIC
User manual 36 pages
DSX
User manual 40 pages
DSX
User manual 28 pages
DLX24
User manual 20 pages
CDX 7-U
User manual 9 pages
CDX 7-U
User manual 40 pages
CDX 7-U
User manual 56 pages
CDX 7-U
User manual 88 pages
CDX 7-U
User manual 92 pages
CDX 7-U
User manual 108 pages
CDX 11-U
User manual 9 pages
CDX 11-U
User manual 40 pages