Log in


or


google Continue with Google

Already have an account?

Fluke T140 (172 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 3
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The Fluke T140 is a high-precision temperature testing device designed for accurate and reliable temperature measurements in various industrial and commercial applications. It features a durable construction, a large digital display for easy reading, and a wide measurement range. The device is equipped with a thermocouple input for compatibility with different temperature sensors. It offers fast response times and high accuracy, making it suitable for use in environments where precise temperature monitoring is essential. The Fluke T140 is ideal for professionals in fields such as HVAC, electrical engineering, and process control.

Frequently Asked Questions

What is the maximum voltage these testers can measure?

The Fluke T100/T120/T140 voltage testers can measure DC and AC voltages up to 690V. They are designed for use in voltage systems within this range.

What safety standards do these testers comply with?

These testers comply with safety standards including IEC 61140 for insulation, IEC 60529 for IP ratings, and the Low Voltage Directive (73/23/EEC). They are also VDE-approved and meet the requirements of the WEEE Directive.

How do I perform a voltage test?

To perform a voltage test, connect both test probes to the unknown circuit. The tester will automatically switch on if the voltage is above 12V. The LED and LCD (for T120/T140) will indicate the voltage level, with polarity shown for DC measurements.

What is the purpose of the single-pole phase test?

The single-pole phase test is used to detect live conductors in a circuit. It starts at approximately 100V AC and illuminates the corresponding LED. However, it is not suitable for determining if a line is live; a double-pole test is required for this purpose.

Can these testers be used with RCD circuit breakers?

Yes, these testers can be used with RCD circuit breakers, but they may trigger the RCD during testing. To avoid this, test between L and N for about 5 seconds first, then test between L and PE without triggering the RCD.

What should I do if the tester does not function properly?

If the tester does not function properly, first check the batteries and ensure they are fully charged. If the issue persists, verify the integrity of the test leads and the connections. If the problem continues, the tester should be serviced by an authorized technician.

What is the IP rating of these testers?

The Fluke T100/T120/T140 testers have an IP65 rating, which means they are dust-tight and protected against water jets from any direction, making them suitable for use in harsh environments.

How do I test for continuity?

To test for continuity, connect the test probes to the circuit under test. The continuity LED will illuminate if a short circuit or low resistance is detected, indicating a potential fault in the circuit.

What is the purpose of the double-pole phase test?

The double-pole phase test is used to determine the direction of the alternating current in a circuit. It helps identify the correct phase rotation and is essential for ensuring proper wiring in three-phase systems.

Send answer

Additional user manuals for the same series

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.