Product description:
Frequently Asked Questions
How do I know if the voltage tester is working properly?
Before using the tester, verify its operation by measuring a known voltage and connecting the test probes together. If there is no response, replace the battery first or have the meter serviced.
What should I do if the voltage tester does not show 'voltage present'?
It is highly recommended to install earthing equipment before starting work if the 'voltage present' indication does not appear.
What happens if the voltage tester detects a voltage but the part is expected to be disconnected?
It is highly recommended to confirm by another means, such as using an adequate voltage detector or visually checking the disconnecting point, that there is no operating voltage on the part to be tested. The voltage indicated may be an interference voltage.
What is the maximum voltage the tester can handle?
The tester should not be connected to voltages higher than 750V. It is designed for use on installations with the specified nominal voltage or nominal voltage ranges.
How do I perform a continuity test?
The continuity test is only possible when batteries are installed and in good condition. Ensure the tester is functioning correctly before performing the test.
What is the accuracy of the voltage measurement?
The accuracy for AC voltage is ± (1.3% + 5d), and for DC voltage it is ± (1.0% + 2d). These values are based on the specified conditions outlined in the manual.
How do I test for phase rotation?
To test phase rotation, connect the test electrodes to two phases of a three-phase power supply connected in clockwise rotation. A symbol will appear in the LCD display if the rotation is clockwise. If the rotation is anticlockwise, a different symbol will be displayed. Both phases should be switched around in this case.
How do I perform an RCD voltage test?
To test RCD trip, measure the voltage between L and PE. To avoid tripping, perform a test between L and N for approximately 5 seconds, then proceed with voltage testing between L and PE without causing an RCD trip.
What should I do if the battery compartment is opened?
If the symbol indicating low battery is displayed, completely disconnect the tester from the measurement circuit. Unscrew the battery cover, remove the discharged batteries, replace them with new 1.5V IEC LR03 batteries, ensuring correct polarity, and close the battery cover again.
What is the warranty period for the TP3500LCD?
The TP3500LCD is covered by a two-year warranty. If the instrument functions improperly during normal use, it will be repaired or replaced free of charge, provided it is returned unopened and undamaged. Damage due to dropping or incorrect handling is not covered by the warranty.