PRESIDIUM Adamas (135 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do I power up the Adamas?
To power up the Adamas, connect one end of the 86% cable to the Presidium Universal Adaptor (optional item sold separately) and the other end to the micro 86% port. Alternatively, you can connect the 86% cable to your computer to power up the device. If using batteries, slide open the battery cover and insert 3x AAA batteries, ensuring the positive (+) and negative (-) directions are correct.
How do I turn on the Adamas?
To turn on the Adamas, remove the protective cap from the tester. Press the Power button located at the lower end near the micro 86% port. Wait for about 15 seconds for the tip to warm up to the predetermined temperature. The 'Ready' LED near the power button will blink continuously during the warming period.
What does the 'Ready' LED indicate?
The 'Ready' LED indicates that the Adamas is warming up. It will blink continuously during this period. Once the device is ready for use, the LED will stop blinking, signaling that the tester is operational and prepared for testing.
What are the key features of the Adamas?
The Adamas features a replaceable probe tip, a micro tip for measuring diamonds as small as 0.01ct, a retractable tip for consistent pressure, a calibration key for accuracy, a 86% cable for power, a chrome grip for comfort, international voltage compatibility, a low battery indicator, and automatic power-off after 2 minutes of inactivity.
How do I replace the probe tip?
The Adamas allows users to replace the probe tip at any time without returning the device to the manufacturer. Simply remove the old tip and insert a new one, then perform a calibration to ensure accuracy. The micro tip is an optional accessory sold separately.
What should I avoid when using the Adamas?
Avoid exposing the Adamas to liquids, moisture, extreme temperatures, or cold environments, as these can damage the device or affect its performance. Do not attempt to open the device yourself, and avoid using harsh chemicals or detergents for cleaning.
What happens if the Adamas gets wet?
If the Adamas gets wet, remove the battery immediately and allow the device to dry completely before using it again. Moisture can cause damage to internal electronic components and affect the accuracy of the readings.
How do I calibrate the Adamas?
To ensure accuracy, use the calibration key provided with the device. Follow the instructions in the user manual to perform a calibration. This process helps maintain the device's precision and reliability over time.
What is the warranty coverage for the Adamas?
The Adamas is covered under the Presidium warranty, which applies only to manufacturing defects. The warranty does not cover damage caused by improper use, exposure to extreme conditions, or failure to follow the provided instructions. Always refer to the warranty card for detailed terms and conditions.
How long does the Adamas operate on batteries?
Using alkaline batteries, the Adamas can operate for approximately 12 hours of continuous use. Ensure that you use the correct battery type and orientation to maximize battery life and maintain accurate performance.