Product description:

The Swegon CASA R85 is a testing device designed for use in ventilation systems. It is used to measure and analyze air flow and pressure conditions within ducts. The device features a robust construction and precise measurement technology, ensuring reliable results in various installation environments. It is suitable for both indoor and outdoor applications and supports quick and accurate testing of ventilation performance.

Frequently Asked Questions

How to safely open the unit for maintenance?

Before opening the unit for maintenance, ensure the power supply is disconnected. Wait a few minutes for the fans to stop and any heating elements to cool down. The unit's lock mechanisms are located under the cover plates at the top and bottom of the door. Remove the cover plates carefully and open the door by lifting it gently.

How often should filters be cleaned or replaced?

Filters should be cleaned at least every six months using a vacuum or brush, and replaced at least once a year. If the environment has high levels of dust or pollutants, more frequent cleaning or replacement may be necessary. Never operate the unit without filters, and only use Swegon-approved filters.

What are the different operating modes and when are they used?

The unit has three operating modes: 'Away' for low air exchange when the building is unoccupied, 'Home' for normal air exchange, and 'Boost' for increased ventilation during cooking, sauna use, or drying. The 'Boost' mode runs for 60 minutes before returning to 'Home' speed. These modes can be controlled via the Premium control panel or the Premium thermostat.

How does the frost protection function work?

The frost protection function activates during winter when the temperature difference between indoor and outdoor air is small and the exhaust air is cold. It reduces the exhaust fan speed and increases the intake fan speed for about 10 minutes, creating a temporary overpressure in the building to force the exhaust of stale air. This function can be deactivated by pressing the button again.

What does the status light on the control panel indicate?

The status light on the control panel shows the unit's operation in different colors. A green light indicates normal operation, an orange light indicates a stopped heat exchanger, and a red light indicates a fault. A flashing red light means there is a system malfunction, and you should contact service. A flashing yellow light indicates the automatic frost protection function is active.

How to set the thermostat and ventilation modes?

To set the thermostat and ventilation modes, navigate to the 'Settings' menu on the control panel. Choose the desired operating mode (Home, Away, Boost) and adjust the fan speeds accordingly. The unit can also be programmed with a weekly timer to automate these settings, though manual adjustments can override the timer.

What should I do if the unit displays a fault message?

If the unit displays a fault message, such as 'Sensor Fault,' contact service immediately. The status light will flash red to indicate a malfunction. Do not attempt to reset the unit yourself unless instructed to do so. Fault messages may indicate issues with sensors, filters, or the heat exchanger.

How to reset the maintenance reminder?

To reset the maintenance reminder, navigate to the 'Service and Maintenance' menu on the control panel. Select 'Maintenance Reminder' and follow the on-screen instructions to clear the reminder. This should be done after completing maintenance tasks to ensure the reminder is reset correctly.

What are the safety precautions when servicing the unit?

Always disconnect the power supply before servicing the unit. Wait a few minutes for the fans to stop and any heating elements to cool down. Do not attempt to service the unit unless you are a qualified technician. Ensure the unit is not restarted until the cause of any fault has been identified and the unit has been properly serviced.

How to check the filters for blockage or damage?

To check the filters for blockage or damage, open the unit's maintenance panel and inspect the filters visually. If the filters are dirty or damaged, clean or replace them immediately. Ensure that the filters are installed correctly and that there are no gaps or leaks in the filter housing. Regular inspection helps maintain optimal airflow and system efficiency.