Log in


or


google Continue with Google facebook Continue with Facebook

Already have an account?

VOLTCRAFT MT-51 (72 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

Product description:

The VOLTCRAFT MT-51 is a multifunctional testing device designed for precise measurement of electrical parameters. It offers accurate voltage, current, and resistance measurements, making it suitable for use in electrical installations and maintenance tasks. The device features a clear digital display and is equipped with various test functions to support a wide range of applications. Its compact and robust design ensures ease of handling and durability in professional environments.

Frequently Asked Questions

What is the maximum voltage for AC and DC measurements?

The MT-51 Multitester can measure voltages up to a maximum of 250 V DC or AC RMS. This includes both direct current (DC) and alternating current (AC) measurements, making it suitable for a wide range of electrical testing scenarios.

What types of measurements can the MT-51 Multitester perform?

The MT-51 Multitester is capable of measuring voltage, current, resistance, and temperature. It also supports diode testing, continuity checks, and can measure ambient light intensity, relative humidity, and sound levels. Additionally, it can perform transistor tests and has a built-in non-contact voltage sensor.

What safety precautions should be taken when using the MT-51 Multitester?

Always ensure the device is disconnected from the circuit before performing any measurements. Avoid touching live circuits or components with voltages exceeding 25 V AC or 35 V DC. Use only the specified battery type and replace batteries promptly to prevent leakage or damage. Never attempt to repair the device yourself; only qualified personnel should handle maintenance or repairs.

How do you replace the battery in the MT-51 Multitester?

To replace the battery, first turn off the device and disconnect it from the circuit. Remove the battery compartment cover using a screwdriver, take out the old battery, and insert a new 9V alkaline battery (type 6LR61, MN1604, 6F22, or 006P) ensuring correct polarity. Secure the compartment and reassemble the device carefully.

What is the function of the HOLD button on the MT-51 Multitester?

The HOLD button allows you to freeze the displayed measurement value for later reference. When you press the button, the measurement is stored, and the display shows 'HOLD', making it useful for comparing values or recording data without continuous monitoring.

How do you measure AC voltage with the MT-51 Multitester?

To measure AC voltage, connect the black probe to the COM port and the red probe to the V/Hz/%/VACRMS/ºC port. Set the range switch to the AC voltage position (V~). Ensure the device is properly connected to the circuit, and the measured value will be displayed. For frequency or duty cycle measurements, use the MODE button to switch between these functions.

What is the purpose of the REL button on the MT-51 Multitester?

The REL button enables relative measurements, allowing you to compare current or voltage readings against a stored reference value. When you press the REL button, the display shows 'REL', and subsequent measurements are displayed as the difference between the stored value and the new measurement, useful for tracking changes or deviations.

What are the technical specifications of the MT-51 Multitester?

The MT-51 Multitester can measure resistance up to 2 MOhm, current from 0.1 μA to 10.00 A, and temperature from -20°C to 1300°C. It also measures light intensity up to 40,000 Lux, relative humidity between 25% and 95%, and sound levels from 35 dB to 100 dB. It includes a non-contact voltage sensor for safe voltage detection.

How do you measure DC voltage with the MT-51 Multitester?

To measure DC voltage, connect the black probe to the COM port and the red probe to the V/Hz/%/VACRMS/ºC port. Set the range switch to the DC voltage position (V=). Ensure the device is properly connected to the circuit, and the measured value will be displayed. The polarity of the measurement is shown, with a negative sign indicating reverse polarity or a negative voltage.

What is the function of the background illumination on the MT-51 Multitester?

The background illumination feature enhances visibility of the display in low-light conditions. To activate it, press the illumination button. To turn it off, press the same button again. This is particularly useful when working in dimly lit environments or for better readability of the measurement values.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5