Waeco Multi Gas (128 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to turn on the leak detector?
Press the START button to power on the device. The sensor will regenerate for 35 seconds, the LED bar display will light up from left to right, and a signal tone will sound. The device is ready for use. If no input is given for 10 minutes, it will automatically turn off.
How to adjust sensitivity?
The device has four sensitivity levels for each refrigerant (R-1234yf or R-134a). Set the sensitivity level based on the suspected leak size. The default settings are sensitivity level L and R-134a mode. For heavily contaminated areas, press the START button again after turning on to switch to a contaminated area mode, which will produce a louder signal tone when a leak is detected.
How to detect a leak?
Ensure the air conditioning system is turned off but has a minimum pressure of 3.5 bar. Check visible areas for oil leaks, damage, and corrosion. Turn on the device using the START button. Select the appropriate sensitivity level based on the suspected leak size. Move the sensor head slowly (3 cm/second) over the components being checked. Remove service plug caps and check for tightness. A signal tone will sound if a leak is detected.
What are the sensitivity levels for R-134a?
For R-134a, the sensitivity levels are: L (14 g/a or higher), M (7 g/a or higher), and S (4 g/a or higher). These levels help detect leaks of varying sizes. Adjust the sensitivity based on the suspected leak size for accurate detection.
What are the sensitivity levels for R-1234yf?
For R-1234yf, the sensitivity levels are: L (14 g/a or higher), M (7 g/a or higher), and S (4 g/a or higher). These levels help detect leaks of varying sizes. Adjust the sensitivity based on the suspected leak size for accurate detection.
How to switch between refrigerant modes?
Press the START button to switch between R-1234yf mode and R-134a mode. This allows the device to detect leaks of different refrigerants accurately. Ensure the correct mode is selected based on the refrigerant type being checked.
How to turn off the leak detector?
Press and hold the START button until the display turns off. The device will power off completely. This ensures the device is not left on unnecessarily and conserves battery life.
What is the purpose of the LED bar display?
The LED bar display shows the size of the leak and helps locate its exact position. The more bars that light up, the larger or closer the leak is. This visual indicator allows for quick and accurate leak detection.
What should I do if the device detects a leak?
If a leak is detected, a signal tone will sound. Ensure proper ventilation to allow smaller leaks to be detected. If a leak is detected using the lowest sensitivity level, perform another test with the next higher sensitivity level to determine the exact size of the leak.
What should I do if the device is not working properly?
If the device is not functioning correctly, check for visible damage or moisture on the sensor. Clean any dirty areas and remove moisture. If the issue persists, contact a qualified technician for repair. Do not attempt to repair the device yourself to avoid potential hazards.