Product description:
Frequently Asked Questions
How to turn on the Wöhler RL 200?
To turn on the device, briefly press the power button. The device will start a 30-second warm-up period during which a red bar will blink on the display. Once the display shows 0 and the alarm tone sounds, the device is ready for use.
How to turn off the Wöhler RL 200?
To turn off the device, hold the power button for 3 seconds. The device will automatically shut down after this period. Ensure the device is in a non-contaminated environment, such as outdoors, before turning it on.
How to silence the alarm tone?
To deactivate or reactivate the alarm tone, press the mute button. The alarm tone icon will light up only when the alarm tone is active. This allows you to temporarily disable the sound without turning off the device.
How to reset the sensor?
To reset the sensor, press and hold the reset button for a few seconds. This will manually set the current ambient refrigerant concentration to zero. The device will then recalibrate its sensitivity for accurate leak detection.
What is the detection range of the Wöhler RL 200?
The Wöhler RL 200 can detect refrigerants with a lower static detection limit of 3 g/a and a lower dynamic detection limit of 3 g/a, even in contaminated environments. It provides both visual and acoustic signals to indicate the presence of refrigerant.
What refrigerants can the Wöhler RL 200 detect?
The Wöhler RL 200 can detect a wide range of refrigerants including FCKW (R11, R12, R500, R503), HFCKW (R22, R123, R124, R502), HFKW (R134a, R404a, R410a, R407C, R32), and others such as R290, R600a, and R1234YF.
How long does the battery last?
The Wöhler RL 200 is powered by 3 AA alkaline batteries and can operate for up to 7 hours continuously. The device will automatically shut off after 30 minutes of inactivity to conserve battery life.
What is the operating temperature range?
The Wöhler RL 200 can operate within a temperature range of -0°C to 50°C. It is designed for use in various environmental conditions, provided the relative humidity does not exceed 80% RH and the air is not condensing.
How to calibrate the sensitivity?
To adjust the sensitivity, use the sensitivity button to select the desired level. This allows the device to detect leaks at different concentrations, improving accuracy based on the specific conditions of the refrigerant system being tested.
What should I do if the device detects a refrigerant leak?
If the device detects a refrigerant leak, the display will show a leak level from 1 to 7, with 7 being the highest. The alarm tone will also increase in frequency with higher refrigerant concentration. Ensure the area is well-ventilated and locate the source of the leak for proper repair.