Product description:
Frequently Asked Questions
What is the intended use of the TR34 resistance thermometer?
The TR34 resistance thermometer is designed for general-purpose temperature measurement in liquid and gaseous media. It can measure temperatures from -50 … +150 °C or -58 ... + 302 °F (without neck tube) and -50 … +250 °C or -58 ... +482 °F (with neck tube). It is suitable for pressures up to 140 bar with a 3 mm sensor diameter and up to 270 bar with a 6 mm sensor diameter, depending on the instrument version. The thermometer is intrinsically safe for use in hazardous areas.
What safety precautions must be followed when using the TR34 thermometer?
Before installation, commissioning, and operation, ensure the correct resistance thermometer is selected based on measuring range, design, specific conditions, and materials. Follow all safety instructions in the manual. Avoid operating the instrument outside its technical specifications, as this may cause damage or injury. If the instrument is moved from a cold to a warm environment, allow time for condensation to form before resuming operation.
Who is considered skilled personnel for working with the TR34 thermometer?
Skilled personnel are those trained in electrical systems, with knowledge of country-specific regulations, standards, and directives. They must be able to recognize and avoid potential hazards. They must also be familiar with the relevant safety instructions and be capable of working independently. Unqualified personnel should not be allowed in hazardous areas.
What are the requirements for using the TR34 thermometer in hazardous areas?
The TR34 thermometer is designed for use in hazardous areas and must comply with ATEX directives and national regulations. The plant operator is responsible for classifying zones and ensuring all thermometers are identifiable with respect to safety-relevant characteristics. Electrical screening must be grounded at one end outside the Ex area, and there must be galvanic separation between intrinsically safe and non-intrinsically safe circuits.
What are the consequences of modifying or repairing the TR34 thermometer?
Modifications or repairs to the TR34 thermometer are not permitted, as they may void the guarantee and certification. Such actions can also compromise the intrinsic safety of the device. Always follow the instructions in the manual and consult the relevant type examination certificate and country-specific regulations for installation and use in hazardous areas.
What should be done if the TR34 thermometer is exposed to hazardous media?
When using the TR34 thermometer in environments with hazardous media such as oxygen, acetylene, flammable or toxic gases, or refrigeration plants, ensure compliance with all relevant codes and regulations. Follow additional safety measures for such media, and ensure proper protection against electrostatic discharge (ESD) to prevent damage to sensitive electronic components.
What safety measures are required when working with the TR34 thermometer's electrical components?
When working with exposed circuitry, use grounded work surfaces and personal wrist straps to prevent static discharge. Ensure that first-aid equipment is available and that operating personnel are regularly trained in work safety, first aid, and environmental protection. Only skilled electrical personnel should handle installation and connection of the instrument.
What are the risks of using a defective power supply with the TR34 thermometer?
Using a defective power supply unit, such as one with a short circuit from mains voltage to output voltage, can result in life-threatening voltages at the instrument. Always ensure the power supply is functioning correctly and that the instrument is operated within its technical specifications to avoid serious injury or equipment damage.
What should be done if the TR34 thermometer is damaged?
Damaged thermometers should not be used. The plant operator must ensure that all thermometers in use are identifiable with respect to all safety-relevant characteristics. If a thermometer is damaged, it should be removed from service and replaced with a functional unit to maintain safety and compliance.
What is the purpose of the configuration software WIKAsoft-TT?
The WIKAsoft-TT configuration software allows users to set up and configure multiple TR34 thermometers identically. It supports fault diagnosis, measured value monitoring, and configuration procedures. This software helps ensure consistent and accurate operation of the thermometers, especially in complex or multi-instrument setups.
Related products from WIKA
TR10-B
User manual 68 pages
TC12
User manual 48 pages
TR12
User manual 48 pages
R5502
User manual 52 pages
R5502
User manual 64 pages
S5412
User manual 52 pages
TF35
User manual 52 pages
TF35
User manual 68 pages
TF44
User manual 52 pages
TR57-M
User manual 52 pages
F73.100
User manual 60 pages
F73.100
User manual 92 pages
73
User manual 56 pages
TM 73.01
User manual 56 pages
74
User manual 56 pages
76
User manual 56 pages
54
User manual 60 pages
54
User manual 64 pages
53
User manual 64 pages
CTH6500
User manual 64 pages