Product description:

The Garant XTRIC is a high-performance tool designed for demanding applications. It features a robust construction and advanced materials to ensure durability and long service life. The tool is optimized for precision and efficiency, making it suitable for a wide range of industrial and professional uses. Its ergonomic design enhances user comfort during extended operation. The Garant XTRIC is engineered to deliver reliable performance under heavy loads and in challenging environments.

Frequently Asked Questions

How to mount the XTRIC Zentrischspanner on a machine table?

To mount the XTRIC Zentrischspanner on a machine table, first clean the machine table and the underside of the Zentrischspanner. Position the Zentrischspanner on the machine table, then attach the spannpratzen using the appropriate fastening kit and secure them with screws.

What tools are needed to mount the XTRIC Zentrischspanner on a GARANT ZeroClamp?

To mount the XTRIC Zentrischspanner on a GARANT ZeroClamp, you will need an internal hex key size 6 and 8, an adapter plate (part number 363080), spannbolzen that match the spanntopf, and a cleaning cloth. Clean the underside of the Zentrischspanner, adapter plate, and spanntopf, then screw the spannbolzen into the adapter plate and position it on the Zentrischspanner.

How to adjust the center of the XTRIC Zentrischspanner?

To adjust the center of the XTRIC Zentrischspanner, use an internal hex key size 3 and a countersunk wrench (part number 628600 2). Loosen the clamping screw with the internal hex key, adjust the center using the countersunk wrench according to the engraving on the Zentrischspanner, and then tighten the clamping screw again.

What is the maximum allowable parallelism error for the XTRIC Zentrischspanner?

The XTRIC Zentrischspanner can only be used to clamp workpieces with a maximum parallelism error of 10 angular minutes. For workpieces with a parallelism error greater than 10 angular minutes, use the Zentrischspanner with angle compensation.

What are the safety precautions when using the XTRIC Zentrischspanner?

When using the XTRIC Zentrischspanner, avoid placing hands between the workpiece and the jaws during clamping. Wear protective clothing, gloves, safety glasses, and safety shoes. Ensure that all safety devices are functional and that the machine is secured against unintended restart. Never remove safety devices until the machine has completely stopped.

What is the maximum clamping force and torque for the XTRIC Zentrischspanner?

The XTRIC Zentrischspanner can apply a maximum clamping force of 25 kN at a torque of 85 Nm. Exceeding these values may cause damage to the workpiece or the machine. Always ensure that the clamping force is sufficient to prevent the workpiece from slipping or falling out.

How to adjust the internal clamping force of the XTRIC Zentrischspanner?

To adjust the internal clamping force, use an internal hex key size 5. First, unscrew the spindle nuts from the spindle. Rotate both spindle nuts 180°, then thread them into the guide and symmetrically screw them back onto the spindle using the internal hex key.

What tools are required to mount the XTRIC Zentrischspanner on a LANG Positioning System?

To mount the XTRIC Zentrischspanner on a LANG Positioning System, you will need an internal hex key size 8, spannbolzen for Quick-Point 52, and a cleaning cloth. Clean the underside of the Zentrischspanner and the Quick-Point top surface, then screw the mounting bolts into the Zentrischspanner.

How to install or remove quick-change jaws on the XTRIC Zentrischspanner?

To install or remove quick-change jaws on the XTRIC Zentrischspanner, first clean the interface between the Zentrischspanner and the jaws. Hang the jaw into the dovetail and push it down using the spring plates. To remove, pull the jaw from the underside or use a screwdriver to lift it off.

What are the maintenance requirements for the XTRIC Zentrischspanner?

Regular maintenance of the XTRIC Zentrischspanner includes lubricating the spindle and guides. Use a suitable lubricant to ensure smooth operation and prevent wear. Inspect the machine for any signs of damage or wear, and replace any worn parts promptly. Keep the Zentrischspanner clean and free from debris to maintain optimal performance.