Product description:

The IKA S 65 KD-G 65 G is a laboratory stirrer designed for efficient mixing and agitation tasks in scientific and industrial settings. It features a powerful motor with variable speed control, allowing for precise adjustment of stirring rates to suit different viscosities and volumes. The device includes a robust, detachable stirring shaft made from durable materials, ensuring compatibility with various containers and resistance to chemical exposure. Its compact, stable base facilitates easy setup on workbenches, while integrated safety mechanisms help prevent overheating and motor overload. This model supports a range of applications, such as sample preparation in chemistry and biology, with reliable performance for consistent results.

Frequently Asked Questions

How do I adjust the stirring speed on the IKA S 65 KD-G 65 G?

The S 65 KD-G 65 G uses a variable speed control knob that lets you set rpm precisely for different viscosities. Adjust gradually from low to target speed to avoid splashing, and observe torque to prevent overload. For best results, start slow and increase until achieving a homogeneous mixture.

What range of viscosities and sample volumes can this laboratory stirrer handle?

This model handles a wide range of viscosities from low to moderately high and is suitable for typical sample volumes used in chemistry and biology. For very viscous media or very large volumes, select appropriate shaft geometry and slower speeds to maintain efficient mixing without overloading the motor.

What type of motor does the IKA S 65 KD-G 65 G use and what are the benefits?

The unit features a robust, high-torque motor designed for continuous laboratory use with overload protection. The motor provides stable speed under load, ensuring reproducible mixing. Benefits include consistent performance, reduced heating, and reliable operation when matching shaft and speed to the sample.

Which materials are used for the stirring shaft and how resistant is it to chemicals?

The detachable stirring shaft is made from chemically resistant, durable materials such as stainless steel or coated alloys to withstand common laboratory reagents. This resistance reduces corrosion risk and contamination; still, verify chemical compatibility with aggressive solvents and replace shafts if surface damage occurs.

How do I install or remove the stirring shaft safely on this model?

Ensure the device is powered off and stationary, then align the shaft with the coupling and insert until it locks securely. To remove, power down and carefully release the coupling before pulling out the shaft. This prevents injury and protects the coupling and shaft from damage.

What integrated safety features protect the device from overheating or motor overload?

The S 65 KD-G 65 G includes thermal protection and overload cutoff that halt operation if temperature or current exceeds safe limits. These features extend motor life and protect samples; if safety trips occur repeatedly, reduce load, check shaft alignment, and allow cooling before restarting.

Which container types and holder setups are best for stable operation?

Use rigid, flat-bottomed containers with appropriate clamps or stands to ensure alignment and stability. Select holder positions that keep the shaft centered and avoid contact with container walls. Properly balanced setups minimize vibration and improve reproducibility of mixing results.

How should I clean and maintain the stirrer to ensure long-term performance?

Wipe down exterior surfaces regularly with compatible cleaning agents, remove and clean the shaft after each use, and inspect seals and coupling for wear. Periodic checks of mounting screws and electrical cords help prevent failures. Avoid immersing the motor housing in liquids.

Can the S 65 KD-G 65 G run continuously for extended periods?

Yes, the device is designed for prolonged laboratory use, but continuous runtime depends on operating conditions and load. Monitor motor temperature and use built-in protection features. For long runs, select appropriate speed and impeller to minimize stress and allow periodic cooldown if necessary.

What are common troubleshooting steps for motor stalls or irregular stirring speed?

If the motor stalls or speed fluctuates, first reduce load and power down, check shaft alignment and secure coupling, and inspect for obstructions or excessive viscosity. Allow the motor to cool and then restart at low speed. If problems persist, have the unit inspected by qualified service personnel.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.