Product description:

The HBM P2VA1 is a high-precision transmitter designed for use in industrial measurement applications. It features a robust construction suitable for harsh environments and ensures reliable signal transmission. The device supports various input signals and offers adjustable output ranges for flexible integration into different systems. Its compact design allows for easy installation and maintenance, making it a versatile solution for a wide range of measurement tasks.

Frequently Asked Questions

What are the safety instructions for using the P2VA1/P2VA2 pressure transmitter?

The P2V pressure transmitter is intended solely for pressure measurement and related control tasks. It must be used strictly according to the operating manual, with adherence to legal and safety regulations. The device does not qualify as a safety element in its intended use. Proper installation, storage, handling, and operation are essential to ensure safe usage.

What happens if the zero signal of the pressure transmitter changes significantly?

A significant change in the zero signal indicates that the device has reached the end of its service life. This may be due to factors such as temperature extremes or physical damage, which can affect the accuracy and reliability of measurements.

What are the symbols used for safety warnings on this manual?

The following symbols indicate different levels of danger: DANGER (maximum risk), WARNING (potentially dangerous situation leading to serious injury), CAUTION (potential damage or minor injury), and NOTE (important information about product handling). These help users identify critical safety considerations.

What is the maximum pressure rating for the P2VA1/P2VA2 transducer?

The P2VA1 and P2VA2 are rated for a measurement range of 100 to 7000 bar. The specific model determines whether it can handle up to 2000 bar, 3000 bar, or 7000 bar depending on the application requirements.

What is included in the standard scope of supply for P2VA1/P2VA2?

The standard package includes one pressure transducer (either voltage or current output), a 5-meter shielded cable with M12x1 connector, and mounting instructions. Additional items such as seals and connection adapters may be ordered separately based on the required measurement range.

How is the P2VA1/P2VA2 pressure transducer connected to the system?

The transducer connects via a G1/4" external thread for lower ranges (up to 2000 bar) or an M16x1.5 thread for higher pressures. A tapered seal made of corrosion-resistant material is included, ensuring secure and leak-proof installation.

What should be done if the transducer needs recalibration or repair?

When sending the device to HBM for calibration or repair, specify the pressure medium used. This helps identify any residual substances in the measuring aperture, allowing appropriate cleaning agents to be selected and ensuring accurate service.

What is the purpose of the blow-off opening on the transducer housing?

The blow-off opening allows controlled release of overpressure if the sensing element ruptures. This prevents damage to the sensor housing by releasing excess pressure safely, typically at around 10 bar.

Can the P2VA1/P2VA2 be modified without manufacturer approval?

No modifications are allowed unless explicitly approved by HBM. Any changes void all liability for damages resulting from such alterations and may compromise safety or performance specifications of the device.

What is the TEDS system used for in this pressure transmitter?

The TEDS (Transducer Electronic Data Sheet) digital identification system allows transfer of calibration data, sensor characteristics, and adjustment parameters to the transducer during production. It ensures accurate signal correction by compensating for factors like temperature drift and linearity errors.