Product description:
Frequently Asked Questions
Can the KPI unit be installed outdoors?
No, the KPI unit must not be installed outdoors. Installing it outdoors can cause electric hazards or leakage.
What are the safety precautions for installing the KPI unit?
Ensure the ceiling slab is strong enough to support the unit. Avoid installing near strong electromagnetic wave sources like medical equipment. Keep the unit at least 3 meters away from such sources. Use appropriate slings when lifting the unit to prevent damage.
What should be done if the KPI unit is installed in a flammable environment?
Do not install the KPI unit in a flammable environment. This can lead to fire or explosion risks. Ensure the installation area is free from flammable gases and materials.
What is the recommended height for installing the KPI unit?
It is recommended to install the KPI unit between 2.3 to 3 meters from the floor level. If installed higher than 3 meters, use a fan to ensure uniform air temperature in the room.
What should be done if the KPI unit is installed near electromagnetic wave sources?
Install the KPI unit at least 3 meters away from electromagnetic wave radiators. If installation near such sources is unavoidable, use a steel box for the remote control switch and a steel conduit for the cable to minimize interference.
What are the requirements for the installation location of the KPI unit?
The installation location should be free from oil, acidic, or alkaline environments. Avoid places with high concentrations of sulphurous gas or flammable gases. Ensure the unit is not exposed to silicon gas, which can cause water leakage and electrical faults.
What should be done if the KPI unit is installed in a hospital or similar environment?
Avoid installing the KPI unit where electromagnetic waves from medical equipment may directly affect the electrical box or remote control cables. Ensure the unit is installed at least 3 meters away from such sources to prevent interference.
What is the procedure for lifting the KPI unit?
Use appropriate slings when lifting the KPI unit to avoid damage. Be careful not to damage the insulation material on the unit's surface. For units with a capacity of 500 m³/h or more, ensure the unit is packaged correctly and handled by two people.
What should be done before installing the KPI unit?
Before installation, check that the KPI unit does not contain any foreign materials. Ensure the unit is clean and free from debris to prevent fire or operational failure. Verify that all components are present and in good condition.
What is the purpose of the electric heater in the KPI unit?
The electric heater is used to protect the heat exchanger element when the outdoor temperature is below -5°C. Ensure the installation of the electric heater complies with national and regional regulations. Refer to the Indoor Units & Complementary Systems Technical Catalogue for more details.
Related products from Hitachi
RB160EF
User manual 128 pages
RB160EF
User manual 156 pages
KPI-1002X4E
User manual 128 pages
KPI-2002E4E
User manual 128 pages
KPI-1502E4E
User manual 128 pages
KPI-502E4E
User manual 128 pages
KPI-802E4E
User manual 128 pages
KPI-502X4E
User manual 128 pages
KPI-802X4E
User manual 128 pages
KPI-1002E4E
User manual 128 pages