SystemAir SAVE VSR 500 (212 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum heated living area for the SAVE VSR 300/500?
The SAVE VSR 300/500 is suitable for houses with up to 240/360 m2 heated living area. It supplies filtered outdoor air to residential areas and extracts air from bathrooms, kitchens, and wet rooms.
How should the unit be installed in a cold attic?
When the unit is installed in a cold attic (close to outdoor temperature), it should run continuously. If the unit is intended to be stopped manually or due to a calendar function, install air-tight dampers at the supply and exhaust air ducts to prevent air circulation through the unit.
What should be done if condensation occurs outside the unit?
If condensation occurs outside the unit, increase ventilation in the area close to the unit. This is particularly important in warm and humid areas, such as laundry rooms, where moisture can condense on the casing due to temperature differences.
What is the weight of the VSR 300 unit?
The VSR 300 unit weighs 65 kg. It should be stored and transported in a way that protects it from physical damage, dust, rain, and snow to prevent damage to the unit and its components.
What are the dimensions of the VSR 500 unit?
The VSR 500 unit has dimensions as shown in Figure 2. It weighs 77 kg and should be handled carefully to avoid damage during transport and storage.
What are the airflow level settings for the system?
The system has five airflow level settings: 16% (minimum), 20% (low), 50% (normal), 80% (high), and 100% (maximum). These settings can be adjusted in the Service menu. The airflow levels affect the pressure in the system, which varies depending on the filter type and combination.
What is the power consumption of the SAVE VSR 300/500?
The SAVE VSR 300/500 has a power consumption of 1836 W for the VSR 300 model and 2008 W for the VSR 500 model. The unit comes with a 1670 W re-heater battery, and the fuse size is 10 A for the VSR 300 and 13 A for the VSR 500.
What should be done during storage and installation of the unit?
During storage and installation, the unit and its duct connections should be covered to prevent dust, rain, and snow from entering. Ensure that filters are mounted before starting the unit to avoid damage and ensure proper operation.
What are the duct connections for the SAVE VSR 300/500?
The SAVE VSR 300/500 has duct connections for supply air, exhaust air, outdoor air, and extract air. These connections are shown in Figure 3 with corresponding symbols for each type of air flow.
What should be done if the unit is not running during winter?
If the unit is not running due to late commissioning in winter, the supply and exhaust air ducts should be disconnected and closed to prevent condensation. This is important to avoid damage to the unit and its components during stop periods.
Related products from SystemAir
SAVE VTR 150/B
User manual 112 pages
VR 300 ECV/B
User manual 58 pages
SAVE VSR 300
User manual 58 pages
SAVE VSR 300
User manual 212 pages
SAVE VSR 150/B
User manual 62 pages
KBR
User manual 56 pages
DVNI
User manual 56 pages
DVN
User manual 56 pages
BF Silent 120
User manual 36 pages
BF Silent 150
User manual 36 pages
BF Silent 100
User manual 36 pages
BF X
User manual 40 pages
MONOLIT EC
User manual 40 pages
AxZent
User manual 56 pages
DVN EC
User manual 56 pages
DVV
User manual 56 pages
KBT
User manual 56 pages
MUB/T-S EC
User manual 56 pages
MUB/T-S
User manual 56 pages
MUB/T
User manual 56 pages