How do you install the Eliminator filter?
Install the filter on the boiler return pipe, ensuring the T-piece is aligned with the flow direction. Tighten the collar by hand and secure the isolation valves. Check for leaks after refilling the system.
What is the maximum flow rate for the Eliminator?
The Eliminator is not optimized for flow rates above 25 litres per minute. Ensure the system operates within this limit to maintain efficiency and performance.
How do you open the drain valve?
Remove the end cap, take off the retaining nut, flip the handle, and turn the valve to open. Replace the handle and end cap once the valve is fully open.
How do you close the drain valve?
Turn the valve to the closed position, remove the handle, flip it over, and replace the retaining nut. Secure the end cap to complete the closure.
How do you bleed air from the system?
Open the bleed valve using a screwdriver to release trapped air. Once water starts to escape, close the valve. Repeat if necessary after the system has been running.
What should I do before cleaning the filter?
Ensure the heating system is turned off and allowed to cool. Close both isolation valves to prevent any flow during the cleaning process.
How do you remove the collection bin?
Close the isolation valves, allow the drain water to stop, and unscrew the bin for thorough cleaning. Replace the bin and tighten by hand after cleaning.
What is the recommended inhibitor for the system?
Sentinel recommends using Sentinel X100 Inhibitor to prevent corrosion and limescale formation. Add it to the system after cleaning for optimal protection.
How often should the filter be cleaned?
Sentinel recommends cleaning the filter during the annual system service. Regular maintenance ensures optimal performance and extends the lifespan of the system.
Can the filter be installed vertically or horizontally?
The filter must be installed vertically. The T-piece can be rotated to fit horizontal or vertical piping, but the filter body must always be oriented vertically to ensure proper operation.