Frequently Asked Questions
What is the purpose of the Multidem system?
The Multidem system is a pressure-operated device connected to a water installation, designed for full desalination of drinking water for individual customer applications. It removes total salt content, including heavy metal ions like lead and copper, ensuring clean water for downstream devices.
How does the Multidem system ensure safety during operation?
The system includes a certified backflow preventer, approved by DVGW, which acts as a safety valve. It also ensures compliance with DIN EN 1717 standards, and the filter cartridges are designed to prevent mineral buildup in connected appliances.
What are the typical applications of the Multidem system?
Multidem is commonly used in laboratories and medical settings for steam sterilization and cleaning equipment, as well as in industrial applications such as heating, energy systems, and cleaning processes.
What should be done if the water supply is contaminated?
If the water supply is microbiologically contaminated or of unknown quality, the system should be taken out of operation. After the contamination period ends, the filter cartridges must be replaced, and all connections should be cleaned to ensure safe operation.
How often should the filter cartridges be replaced?
Filter cartridges should be replaced every 12 months or after more than four weeks of stagnation. If the system is not used for over a week, it should be flushed with the specified volume to maintain performance and safety.
What are the safety precautions for installation?
Installation and maintenance must be performed by trained personnel. The system should be protected from sunlight and mechanical damage, and it should not be installed near heat sources or open flames. A shut-off valve must be installed before the filter inlet, and a pressure reducer is required if the water pressure exceeds 8.6 bar.
What is the maximum torque for connecting the filter system?
The maximum torque for G3/8” connections must not exceed 14 Nm. Only hoses with flat gaskets should be used, as conical fittings can damage the filter housing and void the warranty.
What should be done before installing the system?
Before installation, review the technical data and safety instructions. If the product has been stored or transported below 0°C, allow it to acclimate for at least 24 hours at the specified operating temperatures before use.
What is the function of the locking handle on the filter head?
The locking handle securely holds the filter cartridge in place and controls the water flow, ensuring safe and easy operation. It must be engaged properly during installation and maintenance to prevent accidental dislodgement.
What are the requirements for the water used in the system?
Only water of drinking water quality should be used as the feedwater for the Multidem system. It is designed for cold water applications within the specified temperature range and should not be used with microbiologically contaminated or unknown quality water.