Frequently Asked Questions
How to mount the holding angle for Robacta?
To mount the holding angle, use a 5.8 mm drill bit and a reamer for the 6G7 hole to secure the position. The holding angle must be attached with an M8 shoulder screw and an M6 screw. After tightening, insert a 6 mm pin for added security.
How to adjust the holding angle for Robacta?
The holding angle allows for TCP correction on the robot. It can be adjusted so that the arc position remains consistent during robot movement. No additional correction in x or y direction is needed.
What is the recommended torque for assembling the Robacta pipe bend?
Use a torque wrench and a socket wrench for precise tightening. The ideal torque value is 18 ±2 Nm to ensure a secure and defined connection without over-tightening.
How to safely disconnect the cooling system from the welding torch?
Always disconnect the cooling system before starting any work. Ensure that all cooling lines are properly sealed with the plastic cap provided to prevent coolant leakage and potential hazards.
What safety precautions are required when working with Robacta?
Always read and understand the safety instructions in the manual. Ensure all equipment is disconnected from the power source before starting work. Wear protective gear such as heat-resistant gloves and safety goggles to prevent burns and injuries.
How to replace the welding nozzle on Robacta?
To replace the welding nozzle, first turn off the power and disconnect the cooling system. Remove the old nozzle and install the new one, ensuring it is securely fastened. Check for any leaks or damage before resuming operation.
What are the safety risks associated with hot components?
Hot components can cause severe burns and scalding. Allow all hot parts to cool down to at least +25 °C / +77 °F before handling. Use heat-resistant gloves and safety glasses if immediate cooling is not possible.
How to properly install the wire feed unit?
The wire feed unit should be installed with the correct tension and alignment to ensure smooth operation. Follow the manufacturer's guidelines for installation and regularly inspect for wear or damage to prevent malfunctions.
What should be done if the cooling system is not working?
If the cooling system is not functioning, stop the welding process immediately. Check for blockages or leaks in the cooling lines and ensure the coolant is flowing properly. If the issue persists, contact a qualified technician for assistance.
How to maintain the welding torch and its components?
Regularly inspect the welding torch and its components for signs of wear or damage. Clean the nozzle and replace any worn parts as needed. Ensure the cooling system is functioning correctly to prevent overheating and prolong the life of the equipment.
Related products from Fronius
TIG GRINDER MOBILE
User manual 24 pages
TIG GRINDER MOBILE
User manual 188 pages
OPT/i
User manual 12 pages
OPT/i
User manual 48 pages
TP 08
User manual 16 pages
CMT
User manual 20 pages
CMT
User manual 42 pages
TTB 500
User manual 24 pages
TTB 80
User manual 24 pages
OPT/i WF
User manual 24 pages
VIZOR 4000 Plus
User manual 27 pages
VIZOR 4000 Plus
User manual 44 pages
Fazor 1000
User manual 28 pages
THP 300i W
User manual 176 pages
THP 300i W
User manual 304 pages
THP 260i G
User manual 176 pages
THP 260i G
User manual 304 pages
THP 400i W
User manual 160 pages
THP 400i W
User manual 176 pages
THP 400i W
User manual 304 pages