Product description:

The Sauna Control Sentiotec K2 NEXT is a smart sauna controller designed for precise temperature and humidity regulation. It features an intuitive user interface with easy-to-navigate menus and clear display. The device supports multiple sauna modes and can be controlled via a mobile app, allowing users to adjust settings remotely. It is compatible with various sauna types and includes safety functions to prevent overheating. The controller is built with durable materials and is suitable for both residential and commercial sauna installations.

Frequently Asked Questions

How to mount the sauna controller?

Mount the sauna controller outside the sauna cabin at a height of approximately 1.70 meters or as recommended by the cabin manufacturer. Ensure the ambient temperature is between -10 °C and 40 °C. Secure it using a cross-slot screw and attach the wiring through the cable entries.

How to connect the wiring?

Connect the white oven sensor wires to terminal F1 on the terminal block, and the red oven sensor wires to terminal TS. For optional door monitoring, remove the wire bridge from terminal DR and connect the door monitoring wires. Attach the oven, power, and light wires according to the wiring diagram provided.

What is the maximum heating time for the sauna controller?

The sauna controller automatically shuts off after a heating period of 6 hours for safety reasons. This prevents overheating and ensures the system remains within safe operating parameters.

What is the preheating function?

The sauna controller has a preheating function that allows you to set a preheating time in 15-minute increments. The minimum preheating time is 15 minutes, and the maximum is 23 hours and 45 minutes. The sauna heater will turn on automatically after the preheating time has elapsed.

What safety precautions are required during installation?

Installation must be performed by a qualified electrician or similarly trained person. Ensure all work is done in a de-energized state. Use a universal disconnect device with full disconnection according to overvoltage category III. Keep the ambient temperature between -10 °C and 40 °C.

What is the temperature range of the sauna controller?

The sauna controller operates within a temperature range of 40 °C to 125 °C above the oven. It includes an overtemperature protection system that switches off the heater at 139 °C to prevent damage and ensure safety.

How does the sauna controller regulate the temperature?

The sauna controller turns on the heater when the cabin temperature is below the setpoint and turns it off when the temperature exceeds the setpoint. It continues to heat only until the temperature drops back below the setpoint, maintaining a stable and safe environment.

What are the safety instructions for users?

The sauna controller should not be used by children under 8 years old. Children over 8 may use it only under supervision or if they have been shown how to use it safely. Ensure no flammable objects are on the sauna heater before starting the controller or activating the preheating function.

What is the purpose of the door monitoring function?

The optional door monitoring function ensures the sauna heater stops automatically if the door is opened during operation. This prevents accidents and ensures user safety by preventing unintended heating when the sauna is accessed.

What should I do if the sauna heater does not turn on?

Check that the power supply is properly connected and that no flammable objects are on the heater. Ensure the preheating function is set correctly and that the temperature sensors are functioning. If the issue persists, contact your supplier for further assistance.