Product description:
Frequently Asked Questions
What is the power supply range for the PP500?
The PP500 operates on a power supply ranging from 12 to 24 volts DC, with a minimum of 10.5 volts DC and a maximum of 35 volts DC.
What is the power consumption of the PP500-EM?
The PP500-EM consumes approximately 17 mA at 24V DC (408 mW) under normal operation, with a maximum of 31 mA (744 mW) when the horn is active. At 12V DC, it uses about 32 mA (384 mW) typically and up to 68 mA (816 mW) when the horn is active.
What is the operating temperature range for the PP500?
The PP500 can operate within a temperature range of -30°C to +50°C, making it suitable for a wide range of environmental conditions.
What is the IP rating of the PP500?
The PP500 has an IP54 rating, which means it is protected against dust and water jets from any direction, making it suitable for outdoor or harsh environments.
What are the reading distances for the PP500?
The PP500 has different reading distances depending on the technology used. For EM4102 (passive), the reading distance is up to 5 cm. For Cotag (passive), it is also up to 5 cm, while Cotag (active) can read up to 10 cm.
How does the PP500 enter programming mode?
To enter programming mode, press and hold the 'B' button for 2 seconds during power-up. This will activate the red and green LEDs, indicating that the device is in programming mode.
How long does programming mode last on the PP500?
If no cards are presented or short code keys are pressed within 60 seconds while in programming mode, the PP500 will automatically time out and return to normal operation.
How can you exit programming mode on the PP500?
To exit programming mode, press the 'B' button when the red and green LEDs are flashing together, which will stop the programming process and return the device to its normal state.
What is the default configuration for power-up on the PP500?
The default configuration for power-up on the PP500 is BCLINK, which is used for addressable entry/exit functionality.
What is the recommended cable type for the PP500?