How to connect the T124 control unit?
To connect the T124, follow the wiring diagram in Figure 2. Ensure all connections are made according to Table 1 and use appropriate conductors for each function.
What is the power supply requirement for T124?
The T124 requires a 230V AC ±10% input with a frequency of 50/60 Hz. It consumes approximately 100 mA in standby and up to 1A at maximum load.
What are the technical specifications for CB24 battery charger?
The CB24 is an optional battery charger that works with two rechargeable batteries of 12V 1.3Ah each. It provides a charging time of about 10 hours and supports up to four cycles within five hours.
How does the T124 handle motor speed control?
The T124 includes features like soft start, adjustable motor force, and programmable slowdown points. These allow for precise control of the motor's operation during opening and closing movements.
What is the purpose of the phototest function in T124?
The phototest function allows you to check if the photocell system works correctly by triggering a light signal. It helps verify that the gate stops when an obstacle is detected, ensuring safety during operation.
How do I program the opening and closing times for T124?
To set up the working time and pause duration, use the P/P (step/step) button to manually control the motor. After reaching full stop, press P/P again to start the programmed delay before reversing direction.
What is the role of the dip-switch in T124?
The dip-switch allows you to configure various functions such as slowdown points during opening and closing, phototest activation, and other operational settings. Each position corresponds to a specific function according to Table 2.
How do I handle emergency stop functionality in T124?
The STOP button is used for testing purposes only and should not be considered as an emergency safety feature. It allows you to halt the motor during installation or troubleshooting, but it does not provide protection against electrical faults.
What are the recommended practices for wiring T124?
Use separate cables for each function instead of a multi-pole cable. For long runs over 50 meters, use relays near the control unit to prevent signal interference and ensure reliable operation.
How do I install batteries with CB24 charger?
Connect two rechargeable 12V 1.3Ah batteries in series using the provided cables to terminals 1 and 2 of the CB24 module. Ensure correct polarity, then verify that power is supplied correctly before restoring main voltage.