Frequently Asked Questions
What is the maximum power rating for Infrabox basic?
The Infrabox basic can control a maximum heating power of 3.5 kW. It supports switching and dimming modes with different wattage limits, including up to 1.3 kW for half-wave dimming and 350 W for phase-cutting.
What safety precautions are required during installation?
Installation must be performed by a qualified electrician or trained personnel. Ensure all connections are made in a de-energized state, avoid using flammable materials near the infrared heater, and follow local electrical regulations.
What components come with Infrabox basic?
The package includes the control unit, power module, power supply cable, mounting hardware, user manual, and an HV connector. Optional accessories like a foil sensor or IR plug are available for additional functionality.
How to connect the foil temperature sensor (WC4-IRF-F)?
The foil sensor must be connected during installation of the infrared plate. It should be activated and properly wired according to section 5.3, ensuring compatibility with approved IR plates listed in section 2.1.
What are the operating modes for Infrabox basic?
The device supports switching mode up to 3.5 kW, half-wave dimming (up to 1.3 kW), and phase-cutting dimming (up to 350 W). It also includes a timer function and remote start capability.
What safety measures are required for infrared heaters?
Infrared heaters must be connected via an approved temperature limiter if non-safety-rated products are used. Ensure the heater is not covered, avoid flammable materials nearby, and check that all connections meet electrical standards.
What types of infrared heaters are compatible with Infrabox basic?
Approved models include DIR-350-R, WIR-350-R, ECO-350-R, IR-WP-175, and others listed in section 2.1. Always use safety-rated devices or ensure a temperature limiter is installed for non-safety products.
What are the maximum heating times according to EN standards?
EN 60335-2-53 specifies a maximum of 6 hours for private infrared cabins. For commercial use, such as in hotels or residential blocks, up to 12 hours is allowed. Extended operation beyond this requires public facility certification.
How should the power module be mounted?
Mount the power module on a dry surface with maximum ambient temperature of 40°C and humidity of 95%. Ensure proper ventilation to prevent overheating, and avoid covering it with objects or materials.
What is the purpose of the foil sensor in infrared plate operation?
The foil sensor (WC4-IRF-F) measures surface temperature for precise control when using compatible IR plates. It must be connected during installation and activated to ensure safe and efficient heating performance.