The Danfoss CF-MC controller is designed for precise temperature control in heating and cooling systems. It features an intuitive interface and reliable performance, making it suitable for a wide range of applications. The controller supports various communication protocols and can be easily integrated into existing systems. It is built with durable materials to ensure long-term operation under different environmental conditions. The CF-MC is ideal for use in residential, commercial, and industrial settings where accurate and stable temperature regulation is required.

Frequently Asked Questions

How to mount the CF-MC Master Controller?

Mount the CF-MC Master Controller in a horizontal upright position. For wall mounting, remove the front cover and use screws and wall plugs. For DIN-rail mounting, click on the DIN-rail and release when done. Ensure all installations are completed before connecting to a 230 V power supply.

How to connect 24 V actuators?

Connect the two actuator wires to an output. Fix the cable using either a round or squared/flat cable. If NC actuators are used for PWM regulation, no further configuration is needed.

How to connect relays for pump and boiler control?

For the pump, connect the live wire (L) across the Pump Relay from an external power supply, ensuring the power is off before connecting. Repeat the same process for the boiler. Note that these relays are potential-free and cannot be used as direct power supply. Max. load is 230 V and 8 A/2 A (inductive).

How to connect the away function input?

Connect the two wires from an external switch (ON/OFF) to the away function input terminals. When the switch is closed (ON), the system overrides the current set point for all room thermostats and changes it to 8 °C. The away function can be changed using the CF-RC Remote Controller.

How to connect heating and cooling input?

Connect both wires from an external switch (ON/OFF) to the heating and cooling input terminals. When the switch is closed (ON), the system switches from heating to cooling mode. In cooling mode, the actuator output is activated when the room temperature exceeds the set point +2 °C. A dew-point sensor should be installed and connected to the away function input.

How to perform a transmission test (link test)?

The transmission test can be initiated from other system components like the CF-RU Repeater Unit or CF-RC Remote Controller. When the test is received by the CF-MC Master Controller, the assigned output(s) will flash, helping to identify which outputs are connected to which room thermostats.

How to configure actuator outputs?

Activate Output mode on the CF-MC Master Controller and select the desired configuration using the output selection button. The output LEDs will indicate the selected configuration. Options include NC actuators with ON/OFF regulation, NO actuators with ON/OFF regulation, and PWM regulation for floor heating.

How to configure relays for pump and boiler control?

Activate Relay mode on the CF-MC Master Controller and select the desired relay configuration using the output selection button. Options include pump control, boiler control, and combined pump and boiler control. The CF-RC Remote Controller can be used for additional configurations.

How to configure the away function and heating/cooling input?

Activate Input mode on the CF-MC Master Controller and select the desired input configuration using the output selection button. Options include switching to cooling mode when heating/cooling input is activated, or switching to a fixed set room temperature of 8 °C when the away function input is activated.

How to configure heating and cooling in a 2-pipe system?

A 2-pipe system can be configured for automatic heating/cooling change-over by connecting a PT-1000 pipe sensor to the PT-1000 input. Configuration is only possible via the CF-RC Remote Controller.