deville C07335 (88 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the nominal heat output of the C07335 model?
The nominal heat output of the C07335 model is 14 kW, as measured during the standard operation test according to the NF EN 13240 standard.
How much wood should be loaded for optimal performance of the C07342 model?
For optimal performance of the C07342 model, load approximately 300 grams of kindling, which corresponds to an approximate thickness of 3 cm.
What is the maximum air adjustment setting for the appliance?
The air adjustment must be set to its maximum position to achieve optimal performance and ensure proper combustion.
What is the minimum diameter of the chimney duct for the C07342 model?
The minimum diameter of the chimney duct for the C07342 model is 153 mm, as specified in the installation requirements.
What is the minimum cross-sectional area of the chimney duct?
The minimum cross-sectional area of the chimney duct is 2.5 dm², ensuring adequate airflow for efficient operation.
What is the recommended air intake size for the appliance when operating with closed doors?
The air intake section should be at least a quarter of the chimney duct's cross-sectional area, with a minimum of 50 cm² for closed door operation.
What is the required draft pressure for normal operation of the appliance?
A draft pressure of 12 Pa is required for normal operation, ensuring sufficient airflow for complete combustion.
What materials are allowed for the chimney duct?
Allowed materials include terracotta pipes conforming to NF P 51-311, concrete pipes conforming to NF P 51321, composite metal pipes conforming to NF D 35-304 and NF D 35-303, or those with a favorable Technical Approval, refractory bricks conforming to NF P 51302, and non-combustible materials with thermal insulation where necessary.
How should the chimney duct be installed to avoid obstructions?
The chimney duct must be installed in a way that allows full visibility along its entire length and must be mechanically accessible for cleaning. It should also be designed to prevent soot accumulation, especially during cleaning.
What is the recommended height for the chimney duct outlet above the roof?
The chimney duct must exit at least 0.4 meters above the roof ridge and adjacent roofs, ensuring proper ventilation and preventing backdraft issues.