SICK W4F (110 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to align the sensor with the object?
Align the sensor with the object so that the red emitted light beam hits the center of the object. Ensure the optical opening (front screen) of the sensor is completely clear. Refer to the provided diagram for proper alignment.
What is the recommended sensing range for optimal performance?
The recommended sensing range for optimal performance is determined by the object's radiance factor and the minimum distance from the background. Use the characteristic line and bar graph provided in the manual to select the best sensing range for your application.
How to adjust the sensing range using the teach-turn button?
Use the teach-turn button to adjust the sensing range. Rotate the button to set the desired sensing range, ensuring the red light beam hits the object's center. The sensor will adjust its detection range accordingly.
What are the electrical connection requirements for the sensor?
The sensors must be connected in a voltage-free state. Use the specified wire colors and pin assignments for connections. Ensure the power supply is applied only after all electrical connections are established.
What is the maximum tightening torque for the sensor?
The maximum permissible tightening torque for the sensor is less than 0.4 Nm. Ensure the sensor is mounted securely without exceeding this torque to avoid damage.
What is the purpose of the bluePilot blue indicator?
The bluePilot blue indicator shows the operating mode and the switching state of QL1 and QL2. It helps in monitoring the sensor's status during operation and troubleshooting.
What is the minimum distance required for background suppression?
The minimum distance between the set sensing range and the background (white, 90% remission) must be maintained to ensure proper background suppression. This distance is determined based on the object's radiance factor and the sensing range.
What are the safety precautions for installation?
Ensure adequate protection against moisture, contamination, and UV radiation during installation. The device is not a safety component as defined in the Machinery Directive, so follow all safety guidelines provided in the manual.
What is the UL approval requirement for the device?
The device must be supplied from an isolating transformer with a secondary overcurrent protective device that complies with UL 248. Alternatively, it can be supplied from a Class 2 power supply. The UL environmental rating is Enclosure type 1.
How to check the application conditions for the sensor?
Check the application conditions by adjusting the sensing range and distance to the object or background, as well as the radiance capability of the object. Use the provided diagrams to determine the correct sensing range and minimum distance for background suppression.
Related products from SICK
W9-3
User manual 54 pages
W9-3
User manual 144 pages
LFP Inox
User manual 116 pages
LFP Inox
User manual 56 pages
WTB4-3P2100S13
User manual 38 pages
WL12G-3P3572S12
User manual 48 pages
WLA12L
User manual 212 pages
WE34
User manual 164 pages
WS34
User manual 131 pages
WS34
User manual 164 pages
WTF12L
User manual 232 pages
WTF12V
User manual 232 pages
OLS20
User manual 4 pages
PowerProx - WTT12L
User manual 70 pages
PowerProx - WTT12L
User manual 93 pages
PowerProx - WTT12L
User manual 140 pages
PowerProx - WTT12L
User manual 164 pages
RAY10
User manual 144 pages
RAY10
User manual 166 pages
RAY10
User manual 184 pages