Dräger Pac Ex (96 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to turn the device on and acknowledge an alarm?
Press the power button to turn the device on and acknowledge an alarm. This action also serves to switch the device on and confirm any active alarm status.
How to activate the display and perform a display test?
Press the display button briefly to turn on the display for about 30 seconds. Hold the button for more than 5 seconds to keep the display on until the device is turned off. While the button is pressed, all display segments will be shown.
How to check the battery charge level?
Use the battery check button. If the display shows 'BAT 100 VOL.%', the battery is fully charged. If the display shows 'OFF', the device is turned off.
How to switch between measuring ranges?
Press both buttons simultaneously to switch between measuring ranges. This function is available if the operating mode 25.5 is activated. It allows switching between % LEL and VOL.%.
What are the alarm states and how are they displayed?
Alarm states include concentration pre-alarm, main alarm, and battery alarm. These are displayed as 'ALARM', 'A1', 'A2', and 'BAT'. Alarms are also indicated visually and acoustically, such as through a red alarm light and buzzer.
What is the purpose of the passcode?
A passcode is required to access additional operating functions that alter the device's condition or operation. This includes changing settings, activating or deactivating operating modes, and adjusting measurement parameters.
What are the two measuring ranges and how do they work?
The device has two independent measuring ranges: 0 to 100% LEL and 0 to 100% CH4. These ranges can be switched using the appropriate button combination, provided the corresponding operating mode is activated.
How to perform a semi-automatic zero adjustment?
After charging the battery, perform a semi-automatic zero adjustment by pressing both buttons simultaneously. This function is available only if operating mode 25.7 is activated.
What are the safety regulations for using the device?
The device is approved for use in mixtures of flammable gases and vapours with air, but not in oxygen-enriched atmospheres. Special care must be taken when using it near ethylene-oxygen welding operations to prevent uncontrolled ignition.
What should be done if the device is not functioning properly?
If the device is not functioning correctly, refer to the troubleshooting section of the manual. This section provides information on common faults, their causes, and possible solutions to resolve the issue.
Related products from Dräger
X-am 5100
User manual 264 pages
X-am 5100
User manual 288 pages
X-am 5100
User manual 252 pages
FG4500
User manual 16 pages
PX4500
User manual 7 pages
Polytron 7500
User manual 8 pages
Polytron 7500
User manual 8 pages
FG7000
User manual 13 pages
Aerotest Alpha
User manual 148 pages
Aerotest Alpha
User manual 256 pages
Aerotest Alpha
User manual 112 pages
Aerotest Alpha
User manual 16 pages
X-node
User manual 22 pages
X-node
User manual 44 pages
X-node
User manual 84 pages
Aerotest Navy
User manual 36 pages
Aerotest Navy
User manual 112 pages
Aerotest Navy
User manual 148 pages
Aerotest Navy
User manual 256 pages
Alcotest 6810 med
User manual 40 pages