Product description:
Frequently Asked Questions
How does the CO-210 probe indicate carbon monoxide presence?
The CO-210 probe uses a flashing LED and a beeper to indicate the presence of carbon monoxide. The faster the LED flashes and the more frequent the beeper sounds, the higher the CO concentration detected.
What is the measurement range of the CO-210 probe?
The CO-210 probe measures carbon monoxide concentrations between 0 and 1000 parts per million (PPM). It outputs 1 mV dc for each 1 PPM of CO detected, and indicates an over-range condition at 1000 PPM by outputting 5000 mV.
How long does the CO-210 probe operate on a single battery?
The CO-210 probe typically operates for 500 hours on a single 9 V battery. The battery should be replaced when the low battery indicator appears to avoid false readings.
What are the safety levels for carbon monoxide exposure?
Normal background levels are 0-1 PPM. OSHA standards set 50 PPM as the 8-hour average for enclosed spaces and 100 PPM as the exposure limit. At 200 PPM, symptoms like headaches and fatigue may occur, while 800 PPM can lead to dizziness, nausea, and convulsions, potentially resulting in death within 2 to 3 hours.
How does the CO-210 probe establish a baseline?
Before testing, the probe establishes a baseline by detecting CO levels between 0-3 PPM. If CO levels exceed 3 PPM, it does not reset the baseline but starts taking measurements immediately.
What happens during the self-test of the CO-210 probe?
During the self-test, the probe checks the sensor and battery. If the test passes, it begins monitoring with a beep every two seconds. If the test fails, it emits five beeps, a long pause, and another five beeps before turning off.
How do I connect the CO-210 probe to a digital multimeter?
Plug the RJ45 connector into the probe and the probe cable into the voltage and common jacks on the DMM. Set the DMM to the mV dc (or V dc) function and ensure the battery is replaced when the low battery indicator appears to avoid false readings.
What are the common sources of carbon monoxide?
Common sources of carbon monoxide include poorly maintained furnaces, gas heaters, fireplaces, dirty or blocked chimneys, and internal combustion engines such as automobiles, lawnmowers, and blowers.
What is the accuracy of the CO-210 probe?
The CO-210 probe has an accuracy of ±3% or ±2 PPM, whichever is greater. It uses a stabilized electrochemical sensor specific to carbon monoxide, with a typical sensor life of 3 years.
How often should the CO-210 probe be calibrated?
The CO-210 probe should be calibrated once a year by an authorized Fluke service center. During normal use, no adjustments are required, and any necessary adjustments are made during the calibration process.
Related products from Fluke
322
User manual 2 pages
322
User manual 2 pages
322
User manual 20 pages
321
User manual 2 pages
321
User manual 2 pages
321
User manual 20 pages
416D
User manual 2 pages
IRR1-SOL
User manual 210 pages
IRR1-SOL
User manual 210 pages
1550B
User manual 36 pages
9170
User manual 239 pages
9173
User manual 239 pages
917X Series
User manual 239 pages