Fluke IRR1-SOL (210 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What does the Fluke IRR1-SOL measure?
The Fluke IRR1-SOL Irradiance Meter measures solar irradiance in W/m², surface temperature in °F or °C, panel inclination in degrees, and cardinal directions using a compass function. These readings help determine optimal positioning for photovoltaic panels.
How do I measure temperature with the Fluke IRR1-SOL?
To measure temperature, place the meter directly on the PV panel. The internal sensor automatically takes the temperature reading. Alternatively, connect the external temperature probe to the top of the meter and place it on or near the PV panel for accurate readings.
How do I measure irradiance with the Fluke IRR1-SOL?
To measure irradiance, simply place the meter directly onto the PV panel. The internal irradiance sensor will automatically take the reading. Ensure the meter is in direct contact with the panel for accurate results.
How do I measure the inclination of a PV panel?
Place the meter directly on the PV panel to get an accurate tilt measurement. For panels with inclinations different than 0°, press the ZERO button for 2 seconds to reset the angle and measure the true inclination.
How do I use the compass function on the Fluke IRR1-SOL?
To use the compass function, first perform irradiance, temperature, and inclination measurements with the meter aligned with the PV panel. For accurate cardinal direction, hold the meter horizontally (0 to 20° tilt) and point it in the direction the panel faces, away from metal objects.
What is the measuring range for irradiance?
The Fluke IRR1-SOL measures irradiance from 0 to 1400 W/m² with a resolution of 1 W/m². The accuracy is ±(5% + 5 digits) under standard conditions.
What is the temperature measurement range for the Fluke IRR1-SOL?
The Fluke IRR1-SOL measures temperature from -30°C to 100°C (-22°F to 212°F) with a resolution of 0.1°C (0.2°F). The accuracy is ±1°C (±2°F) between -10°C and 75°C, and ±2°C (±4°F) at extreme temperatures.
How do I replace the batteries in the Fluke IRR1-SOL?
To replace the batteries, turn off the meter, remove the battery cover using a screwdriver, and insert four AA alkaline batteries. Replace the cover and secure it with the provided screw. Ensure the batteries are properly installed to avoid false readings.
What is the battery life of the Fluke IRR1-SOL?
The Fluke IRR1-SOL uses four AA alkaline batteries and has a typical battery life of 50 hours, allowing for over 9000 readings. The meter will automatically power off after 30 minutes of inactivity to conserve battery.
What are the operating and storage temperature ranges for the Fluke IRR1-SOL?
The Fluke IRR1-SOL operates between -20°C and 50°C with humidity below 80% (non-condensing). For the FLK-80PR-IRR probe, the operating temperature range is -30°C to 100°C. The storage temperature range is -30°C to 60°C with humidity below 80%.
Related products from Fluke
322
User manual 2 pages
322
User manual 2 pages
322
User manual 20 pages
321
User manual 2 pages
321
User manual 2 pages
321
User manual 20 pages
416D
User manual 2 pages
1550B
User manual 36 pages
9170
User manual 239 pages
9173
User manual 239 pages
CO-210
User manual 88 pages
917X Series
User manual 239 pages