Megger 8 Mk7 AVOMETER (44 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do I ensure safety when measuring voltage?
Before and after making measurements, check that the instrument’s 10 A fuse is intact by selecting the ‘x 1 Ω’ resistance range and performing a continuity test with shorted leads. Use extreme care when measuring voltages above 50 V.
What should I do before connecting to measure current?
Ensure that the circuit is not live before opening it to connect the test leads. Always switch the instrument to either ‘AC ~’ or ‘DC . . .’ as appropriate and select a suitable range. Do not disconnect the leads when changing ranges.
How do I measure resistance safely?
Ensure that the circuit is completely de-energized before making any resistance measurements. The meter must have its own zero adjustment control for each resistance range, which should be checked and set properly to ensure accurate readings.
What type of fuse should I use in the instrument?
The AVO® Model 8mk7 is fitted with a 1 A and a 10 A high breaking capacity ceramic fuse. Replacement fuses must conform to this specification; glass fuses are not recommended due to their low rupturing capacity.
How do I check if the test leads are in good condition?
Ensure that the test leads are clean, with no broken or cracked insulation. Before every measurement, perform a continuity test using the lowest resistance range and shorted leads to confirm there is no damage.
What should I do when measuring high voltage circuits?
Always ensure the correct range is selected before connecting the instrument to the circuit under test. Use fused test leads with High Rupture Capacity fuses for added safety, and check continuity of the leads before each measurement.
How does the meter handle non-sinusoidal waveforms?
The meter assumes a normal sine waveform during calibration; however, significant waveform distortion may affect accuracy. Users should be aware that distorted or near-square wave shapes can produce high readings while peaky waves may give low readings.
How do I reverse polarity on the instrument?
Use the ‘Rev MC’ self-latching push-button to reverse meter deflection when measuring d.c. voltage with reversed polarity, enabling correct reading by adjusting the direction of pointer movement.
What is the overload protection mechanism for the meter?
The instrument has an automatic cut-out feature that breaks the main circuit if overloading occurs in either forward or reverse directions. This provides high-level protection and must not be reset while connected to any external circuit until the fault causing the overload is resolved.
How do I measure voltage accurately on a.c. ranges?
When measuring a.c. voltages, select an appropriate range based on expected values. The readings are taken from scales like 0-3 or 0-10 and multiplied by the corresponding factor (e.g., 10, 100). Ensure that the meter is set to ‘AC ~’ mode for accurate results.
Related products from Megger
DLRO100
User manual 24 pages
DLRO100EB
User manual 18 pages
DLRO100XB
User manual 18 pages
TDR2000/3P
User manual 31 pages
BM224
User manual 12 pages
DLRO2
User manual 12 pages
DLRO2
User manual 40 pages
BM222
User manual 12 pages
BM221
User manual 12 pages
BM223
User manual 12 pages
DLRO100HB
User manual 18 pages
TDR1000/2P
User manual 126 pages
TDR2000
User manual 161 pages
TDR1000
User manual 213 pages