Product description:
Frequently Asked Questions
What is the maximum allowable input voltage?
The device must not exceed the maximum allowable input voltage under any circumstances to prevent severe injury and/or damage to the device.
What safety standards does the device meet?
The device complies with EN 61326, EN 61010-1, and EN 61557 standards, which cover electrical safety, measurement equipment, and insulation resistance testing.
What is the measurement range for loop resistance (L-PE, Hi-Amp)?
The loop resistance (L-PE, Hi-Amp) measurement range is 0.23–9.99 Ω with a resolution of 0.01 Ω and an accuracy of ±(4% of reading + 6 digits).
What is the measurement range for insulation resistance?
The insulation resistance measurement range is 0.125–1000 MΩ with varying resolutions and accuracies depending on the test voltage, such as 125V, 250V, 500V, and 1000V.
What is the accuracy for RCD (FI) testing?
The accuracy for RCD testing is ±(1% + 1 ms) for the specified test currents (x1/2, x1, x2, x5), with a sinusoidal waveform and a test voltage range of 195 V AC–260 V AC (50, 60 Hz).
What is the function of the 'No Trip' mode in loop testing?
The 'No Trip' mode prevents the RCD from tripping during loop testing, allowing the test to complete without interference from the protective device.
What is the purpose of the Zero function?
The Zero function measures the inherent resistance of the test leads and subtracts this value from the loop impedance to ensure a more accurate measurement.
What is the measurement range for earth resistance?
The earth resistance measurement range is 0.000–999.9 Ω with a resolution of 0.001 Ω and an accuracy of ±(2% + 2 digits).
What is the maximum open circuit voltage protection?
The device has a maximum open circuit voltage protection of ±1.5% + 30 digits, ensuring safe operation under varying voltage conditions.
What is the function of the 'Auto' mode in RCD testing?
The 'Auto' mode automatically selects the appropriate test current ratio (x1/2, x1, x2, x5) for RCD testing, optimizing the measurement process for accuracy and efficiency.
Related products from PeakTech
P1665
User manual 44 pages
P 1525
User manual 38 pages
P 1530
User manual 38 pages
P 1535
User manual 38 pages
P 1560
User manual 38 pages
P 2705
User manual 51 pages
9022
User manual 56 pages
9040
User manual 57 pages
1100
User manual 61 pages
4040
User manual 65 pages
9021
User manual 80 pages
DVB-S
User manual 80 pages
DVB-S2
User manual 80 pages
9020
User manual 82 pages
P1205
User manual 104 pages
4035
User manual 120 pages
1300
User manual 169 pages
P1270
User manual 175 pages