Product description:
Frequently Asked Questions
How to insert or replace the battery?
To insert or replace the battery, fully open the device, access the battery compartment cover on the right side using a coin or screwdriver, remove the cover carefully, and place the 9 V block battery with correct polarity. Ensure the gasket is properly seated before closing the compartment.
How to calibrate the dissolved oxygen meter?
To start calibration, press and hold the mode button for approximately three seconds until the device enters calibration mode. Follow on-screen instructions carefully to complete the process accurately.
What are the technical specifications of this instrument?
The DO-600 dissolved oxygen meter features a microprocessor-controlled LC display, automatic temperature compensation (ATC), manual adjustments for salinity and altitude, storage capacity for up to 150 readings, battery status indicator, and options for Celsius or Fahrenheit units.
How do I store measurement data?
To save a reading, press the 'Store' button briefly. To recall stored values, hold the same button for three seconds. You can navigate through saved measurements using this function to review past readings easily.
What is the purpose of the device?
The DO-600 measures dissolved oxygen and temperature in non-conductive, non-flammable liquids. It's suitable for home use, fish tanks, swimming pools, schools, greenhouses, etc., but not recommended for industrial applications.
How to maintain the device?
Ensure regular cleaning with a soft cloth and avoid exposure to extreme temperatures or corrosive substances. Replace batteries promptly when low to prevent damage from leakage. Store in dry conditions away from direct sunlight.
What safety precautions should I take?
Never modify the device, as this may void warranty and cause hazards like short circuits or fire. Keep it out of reach of children and pets. Use only approved batteries and avoid exposing them to heat or physical damage.
How do I adjust temperature units?
To switch between Celsius and Fahrenheit, press and hold the mode button for three seconds until you can select your preferred unit setting in either 'DO' operation mode. This allows flexibility based on regional requirements.
What is included in the delivery package?
The DO-600 comes with a dissolved oxygen meter, 50 ml electrolyte solution, polishing strip, two membrane caps, carry strap, travel case, external measuring probe with temperature sensor, 9 V battery, and user manual.
How to handle the electrode after initial setup?
After first-time use, keep the electrodes moist by filling the membrane cap with electrolyte. Ensure proper sealing of the cap to prevent drying out. If the electrolyte runs low, you can purchase a replacement under Conrad part number 1763049.
Related products from VOLTCRAFT
DT 2 L / k
User manual 42 pages
2368174
User manual 44 pages
2368174
User manual 44 pages
2633254
User manual 44 pages
VC-11840870
User manual 44 pages
VC-12637405
User manual 44 pages
BT-2
User manual 52 pages
Energy Logger 4000
User manual 56 pages
Energy Logger 4000
User manual 58 pages
TT100
User manual 60 pages
PL-125-T2USB
User manual 62 pages
SEM-3600BT
User manual 64 pages
SEM-3600BT
User manual 64 pages
DO-500
User manual 64 pages
LCR 4080
User manual 66 pages
PHT-600
User manual 72 pages
PHT-200
User manual 76 pages
2239527
User manual 104 pages
SDM-2125
User manual 104 pages
Gamma Check Pro
User manual 116 pages