Frequently Asked Questions
How do you remove the control unit cover?
To remove the cover, first turn off the power supply using the plug or main switch. Then loosen the locking screws (A and B), remove the cover, and carefully press lip C slightly to the left while turning the control unit downward.
What tools are needed for replacement?
The required tool is a cross-head screwdriver. Ensure you have this before starting the procedure to avoid delays during installation or removal of components.
How do you disconnect connectors from the control unit?
To remove all connectors, start by taking off the cover and then carefully unplug them from both the top and back sides of the control unit. Make sure not to damage any wiring during this process.
What is the correct order for reassembly?
Reinstalling the new control unit should be done in reverse order. Ensure that no cables are pinched between the housing when assembling, and double-check all connections before restoring power to prevent malfunctions.
How do you change the language setting on the display?
After turning on the device, the screen displays a setup menu where you can select your preferred language. Use the knob to navigate through options and press OK to confirm your selection once it is displayed.
What should be done if error 142 appears after installation?
If error 142 shows up, first check that the cable bundle connected to the pump is properly attached. If the issue persists and the unit was installed in a device before July 2022 (or September 2022 for some models), disable pump communication by following specific steps through the installer menu.
How do you access the installer settings?
To enter the installer menu, press and hold both the BACK and OK buttons simultaneously for seven seconds. This will bring up a technical code selection screen where you can navigate to pump communication settings using the knob.
What is the purpose of the sleep mode on the control unit?
The control unit enters a 'sleep' mode if no buttons are pressed within a certain time. This helps conserve energy and prolongs device life, but it can be activated at any time by pressing any button to resume normal operation.
How do you set the correct date and time?
After turning on the unit, navigate through the setup menu using the knob. Select each field (date or time) one by one, press OK to confirm your selection, and ensure all settings are correctly displayed before saving them.
What should be done after completing installation?
Once you have finished replacing the control unit, make sure to reattach the cover securely using screws A and B. Always restore power last and verify that the device functions properly by checking all settings on the display.