Log in


or


google Continue with Google

Already have an account?

Stahl 9482/33 (76 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 3
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The Module Stahl 9482/33 is a steel module designed for industrial and construction applications. It is characterized by its high durability, stability, and resistance to mechanical stress. The module is manufactured from high-quality steel, ensuring long-term performance and reliability. It is suitable for use in various environments and can be easily integrated into larger systems. The design allows for simple assembly and installation, making it a versatile component for structural and technical installations.

Frequently Asked Questions

What is the function of the Temperature Input Module for Zone 2?

The Temperature Input Module for Zone 2 is designed to connect up to 8 intrinsically safe temperature sensors to the Remote I/O system IS1+. Each channel can be used as an input for resistance thermometers and resistance transmitters in 2-, 3-, or 4-wire technology, or for thermocouples and mV transmitters.

What are the technical specifications of the module?

The module supports resistance thermometers and transmitters with a measurement range of -200°C to +1100°C, and thermocouples with a range of -200°C to +1800°C. It has a measurement accuracy of 0.025% for 8-channel precise mode and 0.02% for 4-channel fast mode. The module is certified for use in gas and dust explosion hazardous areas.

How should the module be installed?

The module must be installed on the BusRail 9494 and must be mounted in a housing that meets the requirements of IEC/EN 60079-0. It must be installed at least 50 mm away from non-intrinsically safe circuits. The module can be mixed with other intrinsically safe and non-intrinsically safe circuits on the same BusRail, provided there is a 50 mm gap between the terminals.

What safety precautions should be taken when using the module?

The module must only be used in its intended application and in explosion-hazardous areas as specified. It must not be modified or altered, as this could lead to serious injury or death. The module must be installed and operated by trained personnel, and all safety instructions must be followed to prevent electrical hazards.

What are the electrical characteristics of the module?

The module has an input resistance of 10 MΩ and supports 2-, 3-, or 4-wire connections. It has a maximum line resistance of 100 Ω per conductor and a maximum current draw of 200 μA. The module is compatible with various temperature sensors, including Pt100, Ni100, and Cu532, with different measurement ranges and accuracies.

How does the module handle faults?

Each input is individually monitored for wire breakage and short circuits. The module provides fault detection and can be configured for either active or inactive fault monitoring. In active mode, the module can detect faults quickly, with response times ranging from 400 ms to 750 ms depending on the configuration.

What is the response time of the module?

The response time of the module varies depending on the configuration. For 8-channel precise mode, the response time is 400 ms for 2-wire connections and 750 ms for 3-wire connections. For 4-channel fast mode, the response time is 400 ms for 2-wire connections and 720 ms for 3-wire connections.

What are the environmental conditions for the module?

The module is designed for use in gas and dust explosion hazardous areas, specifically Zone 2 and Zone 22. It must be installed in a safe area and must be protected from environmental factors such as temperature and humidity. The module is certified for use in these environments and must be installed in accordance with the relevant safety standards.

What are the safety certifications for the module?

The module is certified for use in explosion-hazardous areas and complies with international standards such as IECEx, ATEX, INMETRO, PESO, cFM, SRPS, FM, and Betriebserlaubnis. These certifications ensure that the module meets the necessary safety requirements for use in hazardous environments.

How should the module be maintained and repaired?

The module should be maintained regularly and inspected for any signs of damage or wear. Repairs should only be performed by trained personnel using the correct tools and procedures. The module should be returned to the manufacturer for repair or replacement if it is damaged or not functioning properly.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.