DAB Divertron (121 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum temperature for the liquid being pumped?
The temperature of the liquid being pumped must not exceed 40°C (104°F). This ensures the pump operates safely and prevents damage to internal components.
Can the pump be used for domestic water supply?
Yes, the pump can be used for domestic water supply, but it is essential to comply with local regulations regarding water management and ensure the water is clean and free from contaminants.
What are the maximum dimensions of solid particles that can be pumped?
The maximum size of solid particles that can be pumped is 3 mm (0.12 in). This helps prevent clogging and ensures the pump operates efficiently.
What is the function of the integrated check valve?
The integrated check valve prevents backflow of water and ensures the pump operates efficiently. It also helps in maintaining system pressure and preventing water loss.
How does the pump automatically turn on and off?
The pump automatically turns on and off based on the water demand. When the pressure drops below the cut-in point, the pump starts, and it stops when the pressure is above the cut-in point and there is no flow, after a 10-second delay.
What is the anti-dryrun function?
The anti-dryrun function prevents the pump from running dry by detecting the absence of both flow and pressure for 20 seconds. If this condition is met, the pump stops and enters an alarm state to protect the motor.
What is the recommended maximum height between the pump and the service faucet?
The recommended maximum height between the pump and the service faucet is 20 meters (65.6 ft) for the DIVERTRON 900 and 13 meters (42.6 ft) for the DIVERTRON 650. This ensures efficient water flow and prevents suction issues.
What is the purpose of the air vent valve?
The air vent valve allows the pump to fill quickly by releasing trapped air. If the water level is below the vent valve, a small amount of water may escape through it, ensuring proper priming of the pump.
How should the pump be installed in a well?
The pump should be installed so that the intake is at least 1 meter (3.28 ft) above the well bottom to avoid suctioning sand and impurities. Use rigid metal tubes to suspend the pump and secure them at the top of the well.
What is the function of the anti-burping system?
The anti-burping system prevents false startups caused by water gurgling. It ensures the pump only activates when there is a genuine demand for water, improving efficiency and reducing unnecessary wear on the motor.
Related products from DAB
DIVERTRON 650
User manual 121 pages
DTRON3
User manual 206 pages
DIVERTRON 900
User manual 121 pages
3 MICRA HS
User manual 19 pages
ACTIVE E 30/80 (6)
User manual 20 pages
ACTIVE E 50/50 (6)
User manual 20 pages
ACTIVE EC 25/80 (6)
User manual 20 pages
ACTIVE J 62
User manual 20 pages
ACTIVE J 62
User manual 156 pages
ACTIVE J 62
User manual 224 pages
ACTIVE J 82
User manual 20 pages
ACTIVE J 82
User manual 224 pages
ACTIVE J 82
User manual 156 pages
ACTIVE J 92
User manual 20 pages
ACTIVE J 92
User manual 156 pages
ACTIVE J 92
User manual 224 pages
ACTIVE J132
User manual 20 pages
ACTIVE J132
User manual 156 pages
ACTIVE J132
User manual 224 pages
ACTIVE JC 132
User manual 20 pages