Product description:

The DAB Divertron is a submersible pump designed for use in water supply systems, irrigation, and drainage applications. It features a robust construction that ensures reliable performance even in challenging environments. The pump is equipped with a motor that is sealed against water ingress, making it suitable for operation in submerged conditions. It offers efficient water displacement and is available in various models to accommodate different flow rates and pressure requirements. The Divertron series is known for its durability, energy efficiency, and ease of installation.

Frequently Asked Questions

What applications is the DAB Divertron best suited for?

The DAB Divertron is ideal for domestic and agricultural water supply, irrigation systems and drainage tasks where a submerged pump is required. Its robust design ensures reliable performance in continuous duty, and selecting the correct model delivers the needed flow and pressure while minimizing energy use.

How does the DAB Divertron prevent water ingress into the motor?

The Divertron uses a sealed motor housing with durable sealing elements and a protected rotor chamber to keep water out. This construction reduces the risk of electrical faults and corrosion; regular inspection of the cable entry and seals helps preserve the seal integrity and prolong service life.

What materials are used in the Divertron to withstand submerged conditions?

The Divertron is built from corrosion-resistant metals and engineered polymers designed for submerged operation, which provide strength and longevity. These materials resist wear and chemical exposure, and routine cleaning plus avoiding highly aggressive fluids will maintain performance and extend pump lifetime.

How do I choose the right Divertron model for my required flow and pressure?

Choose a model by calculating your required flow (volume per time) and total head (pressure) including system losses, then match those needs to the pump's performance range. Allow a margin for peak demand and prioritize models that operate near their best-efficiency point to reduce energy consumption.

Can the Divertron operate continuously while fully submerged?

Yes, the Divertron is designed for continuous submerged operation when correctly installed and cooled by surrounding water. Ensure full submergence as required, avoid air pockets around the intake, and monitor for overheating or unusual vibration to maintain continuous, reliable service.

What routine maintenance does the Divertron require and how often should it be performed?

Maintenance typically includes checking electrical connections, inspecting seals and cable condition, cleaning the intake and impeller of debris, and monitoring bearing noise or vibration. Perform visual checks monthly in harsh conditions and a more thorough inspection at least annually or according to operating hours and water quality.

How energy efficient is the Divertron and how can I optimize its energy use?

The Divertron is engineered for good hydraulic efficiency and low operating costs. To optimize energy use, select the correctly sized model, operate near the pump's best-efficiency point, use a variable frequency drive where appropriate, and maintain the pump to avoid efficiency losses from wear or clogging.

What installation accessories improve Divertron performance and protection?

Useful accessories include intake strainers, non-return (check) valves, appropriate discharge fittings, mounting or guide rails and electrical protection like soft-starts or VFDs. These components prevent damage from debris, reduce water hammer, and ensure smoother starting and better long-term reliability.

How can I troubleshoot reduced flow or a Divertron that won’t start?

Common causes are clogged intake or impeller, blocked discharge, low supply voltage, or tripped protection devices. Isolate power, check the intake and impeller for debris, verify electrical supply and control settings, and address wear issues. For electrical or mechanical faults, enlist a qualified technician.

Is the Divertron suitable for pumping abrasive or sandy water?

While the Divertron handles general water and drainage tasks, abrasive or sandy water increases wear on hydraulics and seals. For such fluids, choose sand-resistant options if available, fit pre-filters or settling chambers, and increase inspection and maintenance frequency to limit accelerated wear.