Product description:
Frequently Asked Questions
What are the maximum system impedance values for the DSF200CE, DSF300CE, and DSF420CE?
The DSF200CE, DSF300CE, and DSF420CE can only be connected to a supply with system impedance no more than 0.381 ohm. If necessary, consult your supply authority for system impedance information.
What safety precautions should be taken when installing the pump?
The pump must be installed in a safe environment with proper drainage, correctly sealed and supported piping, and a secure power supply. All steps for safe operation must be followed, and the installation must comply with EN 60335-2-41 and local standards in Europe.
How should the pump be primed before starting?
Before starting, ensure the pump is primed by filling the strainer basket with water, replacing the lid, and checking that it seals on the O-ring. Allow the pump to run to expel any trapped air.
What should be done if the pump does not prime within two minutes?
If the pump does not prime within two minutes, turn it off and repeat the priming process. Continued air presence under the strainer basket lid indicates a leak in the suction piping, which should be repaired to prevent damage.
What are the recommended pipe sizes for each model?
The DSF200CE uses 50mm pipe, the DSF300CE uses 50mm and 63mm, and the DSF420CE uses 63mm. Using smaller pipes is not recommended as it may cause suction difficulties.
What are the power requirements for the Davey StarFlo pumps?
The Davey StarFlo pumps are suitable for connection to a nominal 220-240 volt 50Hz power supply. They are equipped with a flex lead, and if a power outlet is not available within 3 meters, a safe, dry power point must be provided by an electrician.
What should be done if the pump runs dry?
Never run the pump dry, as it may damage the mechanical seals and cause leakage and flooding. Dry running damage is not covered under warranty. The pump incorporates self-resetting thermal overload to reduce potential damage.
How often should the strainer basket be inspected and emptied?
The strainer basket should be inspected frequently through the transparent lid and emptied when a buildup of rubbish is evident. Regular inspection and cleaning are necessary to prevent blockages and ensure optimal performance.
What are the signs of a faulty pump shaft seal?
A leaking pump shaft seal may be indicated by water on the ground under the pump. This can prevent proper operation and may lead to damage if not addressed promptly.
What should be done if the pump does not operate?
If the pump does not operate, check that the power is connected, the motor is not burnt out, and there are no blockages preventing rotation. If the issue persists, contact the supplier or Davey Customer Service Centre for further assistance.
Related products from Davey
StarFlo DSF250CE
User manual 84 pages
StarFlo DSF300
User manual 84 pages
StarFlo DSF420
User manual 84 pages
StarFlo DSF4203FCE
User manual 84 pages
StarFlo DSF420CE
User manual 84 pages
StarFlo DSF420CE
User manual 84 pages
SILENSOR SLL150
User manual 42 pages
SILENSOR SLL300
User manual 42 pages
SILENSOR SLL300
User manual 84 pages
SILENSOR SLL400
User manual 84 pages
SILENSOR SLL400
User manual 42 pages
SILENSOR SLS100
User manual 42 pages
SILENSOR SLS100
User manual 84 pages
SILENSOR SLS300
User manual 42 pages
SILENSOR SLS300
User manual 84 pages
SILENSOR SLL200
User manual 42 pages
SILENSOR SLL200
User manual 84 pages
Silensor
User manual 72 pages
Silensor SLL300E
User manual 84 pages
Silensor SLS150
User manual 84 pages