Pentair CHALLENGER VS2 (124 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do I set the clock on the VS2 Variable Speed Pump?
To set the clock, press and hold the Display button for 3 seconds. Use the '+' and '-' arrows to choose between a 12 or 24-hour time format. Then use the arrows to adjust the time to the correct time of day. The clock will stop blinking once it is set.
What is the default schedule for the VS2 Variable Speed Pump?
The default schedule is designed to provide enough daily turnover to service a typical pool. It includes three speeds with specific durations and RPM settings. See Table 2 for the default schedule details.
How do I activate External Control Only mode?
To activate External Control Only mode, stop the pump by pressing the Start/Stop button, then press and hold the Start/Stop button for 3 seconds. If successful, the LED next to Ext. Control Only will illuminate.
How do I deactivate External Control Only mode?
To deactivate External Control Only mode, stop the pump by pressing the Start/Stop button, then press and hold the Start/Stop button for 3 seconds. If successful, the LED next to Ext. Control Only will turn off.
What are the electrical requirements for the VS2 Variable Speed Pump?
The pump accepts 99-253V, 50 or 60Hz single-phase input power. It must be wired according to the local electrical codes and standards. Always refer to the National Electrical Code. The pump should be installed by a licensed electrician.
How do I connect the pump to external controls?
To connect the pump to external controls, use the low voltage signal provided by the external control system. The wire should be connected as shown in the wiring diagram. The +5V signal (red wire) is the suggested input for the Speed Digital Inputs.
What is the purpose of the bonding lug?
The bonding lug is used to bond the motor frame to the equipment pad. It ensures proper grounding and electrical safety. The bonding conductor must be solid copper and not smaller than 8 AWG (or 6 AWG for Canada).
What should I do if the pump has been stopped via the Start/Stop button?
If the pump has been stopped via the Start/Stop button, it will not run until the Start/Stop button is pressed again to turn it back on. If the Start/Stop LED is illuminated, it indicates the pump is on and will run via Digital Inputs.
How do I use the Pentair® ControlPro™ with the VS2 pump?
To use Pentair® ControlPro™ with the VS2 pump, connect the pump as shown in the wiring diagram. The correct low voltage input comes from ControlPro™, so the ground must be connected to the contactor. Always check the ControlPro manual for more information.
What is the purpose of the check valve in the discharge line?
A check valve in the discharge line prevents reverse rotation of the impeller and motor. It should be used when the pump is used in applications where there is significant height to the plumbing after the pump.
Related products from Pentair
Ultra-Flow
User manual 72 pages
FLECK 5800 SXT
User manual 36 pages
FLECK 5800 SXT
User manual 84 pages
Fleck 2850 NXT2
User manual 36 pages
FREEFLO
User manual 40 pages
FREEFLO FFL-071
User manual 40 pages
IntelliFlo UltraFlow VSD
User manual 242 pages
IntelliFlo WhisperFlo VSD
User manual 242 pages
JUNG PUMPEN WCFIX PLUS
User manual 48 pages
SIMER 5
User manual 48 pages
JUNG WCFIX PLUS
User manual 48 pages
US 102
User manual 50 pages
US 102
User manual 56 pages
US 73 H
User manual 50 pages
US 73 H
User manual 56 pages
US 75
User manual 50 pages
US 75
User manual 56 pages
US 153
User manual 50 pages
US 153
User manual 56 pages
US 105
User manual 50 pages