Product description:
Frequently Asked Questions
What is the maximum capacity of the Evolution Counterweight System?
The Evolution Counterweight System is designed for single person use only and has a maximum capacity of one person. It is not suitable for multiple users or applications exceeding this limit.
What types of roofs is the Evolution Counterweight System approved for?
The Evolution Counterweight System is approved for use on Category 1 roofs, which include concrete and bitumen membrane, and Category 2 roofs, which include asphalt sanded, single ply membrane, and asphalt stone chippings. For other roof types, contact Capital Safety for recommendations.
What are the minimum static and shear loads required for the roof?
For Category 1 roofs, the minimum static load is 852 kg (1880 lbs) and the shear load is 8 kN (1800 lbs). For Category 2 roofs, the minimum static load is 1016 kg (2240 lbs) and the shear load is also 8 kN (1800 lbs). These loads are based on specific plate configurations recommended for the anchor.
What is the maximum permissible free fall distance for the system?
The maximum permissible free fall distance for personal fall arrest systems using the Evolution Counterweight System is 1.8 m (6 ft.). Exceeding this limit may result in serious injury or death.
What is the required clearance distance for a fall to be safely arrested?
A minimum clearance distance of 4.57 m (15 ft.) is required in the fall area to ensure the fall is arrested before the worker strikes the ground or another object. This distance is measured from the onset of the fall to the point where the fall is stopped.
What should be done if the system is used on a roof with stone chippings?
If the system is used on a roof covered with stone chippings, all loose stones must be removed before assembling the anchor device. This is to prevent potential hazards and ensure the system functions safely.
What are the requirements for connecting subsystems with the Evolution Counterweight System?
Connecting subsystems, such as retractable fall arrestors and energy absorbing lanyards, must be capable of limiting fall arrest forces to a maximum of 6 kN (1351 lbs). The deceleration distance for a PFAS must be at least 2 m (6.5 ft.). Ensure compatibility with EN standards and consult Capital Safety for any concerns.
What precautions should be taken when working near sharp edges?
Avoid working where the connecting subsystem or other components may come into contact with unprotected sharp edges. If unavoidable, use a heavy pad or other protective measures over the sharp edge. An energy absorber should be installed between the harness and self-retracting lifeline if using equipment other than the Leading Edge SRL.
What should be done if the system is used in adverse weather conditions?
The Evolution Counterweight System must not be used in adverse weather conditions. The roof surface must be free of frost, snow, standing water, grease, oil, or any lubricating materials that could reduce friction. Avoid areas where water may accumulate to ensure safe operation.
What is the purpose of the Evolution Counterweight System?
The Evolution Counterweight System is designed as a non-penetrating anchor or tie-off point for a Personal Fall Arrest System (PFAS). It is intended for use on flat roofs or structures and is compliant with EN795:1996 Class E standards. It provides secure anchorage for fall protection equipment.