The DBI SALA LAD-SAF is a security device designed for access control applications. It features a robust construction suitable for both indoor and outdoor use. The device supports various authentication methods, ensuring secure and reliable user verification. It is equipped with a durable housing that protects internal components from environmental influences. The LAD-SAF is compatible with multiple systems and can be easily integrated into existing security infrastructures. Its design allows for simple installation and maintenance, making it a versatile solution for a wide range of security needs.

Frequently Asked Questions

What is the maximum weight capacity for the D-ring anchorage?

The D-ring anchorage is designed for use by persons with a combined weight of no more than 310 lbs (141 kg), including clothing, tools, and other equipment. It is important to ensure that only one person is connected to the D-ring at any given time to maintain safety.

How should the top bracket be installed on a ladder?

The top bracket should be installed with the top connection to the top rung and a connection to the third and fourth rungs. Use the provided hardware to secure the rung connections, and torque fasteners to 12-13 ft-lbs (16.3-17.6 N-m). Ensure the bracket is positioned for safe user access when connecting or disconnecting from the system.

What is the recommended tension for the carrier cable?

The carrier cable should be tensioned to ensure proper system operation. The tensioning nut should be tightened until the ring on the tension indicator is sheared off. A small amount of grease on the tension rod threads can reduce the effort required to tension the cable. If insufficient threads are exposed, pull more cable through the saddle clips and repeat the procedure.

What are the load requirements for the top bracket?

The load requirements for the top bracket vary depending on the number of users. For one user, the load is 3,375 lbs (15.0 kN); for two users, it is 4,350 lbs (19.3 kN); for three users, it is 5,325 lbs (23.7 kN); and for four users, it is 6,300 lbs (28.0 kN). These loads must be supported by the structure to ensure safe operation.

What is the purpose of the cable guides?

Cable guides protect the carrier cable from friction against the ladder or structure and prevent excessive side-to-side deflection. They should be installed at approximately 25 ft (7.62 m) intervals along the carrier cable between the top and bottom brackets, and at any point where the cable may rub against the structure. They should also be staggered to reduce wind-induced harmonic effects.

What are the limitations for using the LAD-SAF® system?

The LAD-SAF® system is not intended for use on portable ladders and must be installed on ladders that are generally vertical, at least 75 degrees from horizontal. Fall clearance below the user's feet and the ground must be at least 7 ft (2 m). Environmental hazards such as high heat, caustic chemicals, and high voltage power lines may require additional precautions.

What safety precautions should be taken during installation?

During installation, wear personal protective equipment, including safety glasses and steel-toed shoes. Use personal fall arrest systems when exposed to fall hazards. Avoid connecting the LAD-SAF® sleeve to the same harness D-ring as a climb assist system to prevent interference with proper operation. Ensure that the movement of the sleeve is not restricted by other equipment.

What is the recommended type of harness for use with the LAD-SAF® system?

DBI-SALA recommends using a full body harness with a front attachment for ladder climbing. A body belt is not recommended, as it may cause unintentional release and possible suffocation during a fall. Only DBI-SALA’s detachable cable sleeve should be used with the system, and substitutions of equipment or components must be approved in writing.

How should the bottom bracket be installed?

The bottom bracket should be mounted in-line (vertically) with the top bracket. Use the provided hardware to install the rung clamps and torque fasteners to 12-13 ft-lbs (16.3-17.6 N-m). Ensure the bracket is positioned for safe user access when connecting or disconnecting from the system.

What should be done if the system needs re-tensioning?

Periodic re-tensioning of the system may be necessary, especially in extreme temperature ranges or for very long systems. The tension indicator can be used to check and adjust the tension. Contact DBI-SALA for details on purchasing the tension indicator and for guidance on re-tensioning procedures.