Product description:

The Bosch BAT 115 is a testing device designed for use in electrical installations. It is used to test the functionality of residual current devices (RCDs) and circuit breakers. The device provides accurate measurements and ensures the safety and reliability of electrical systems. It features a clear display and simple operation, making it suitable for both professional and occasional use. The BAT 115 is a reliable tool for electricians and technicians during installation and maintenance tasks.

Frequently Asked Questions

How to replace batteries in BAT 115?

To replace batteries, first remove the screw on the battery compartment cover using a small cross-head screwdriver. Remove the cover, insert new batteries (6 pieces) with correct polarity, and secure the cover. Ensure all batteries are replaced simultaneously if they are weak.

How to install or replace printer paper?

Insert the printer paper roll so that the paper exits under the printer paper roll. Feed the paper end into the paper feed slot. Pull the paper up about 2 cm at the top of the tester. Guide the paper strip through the slotted cover and close the cover. Ensure the paper is properly loaded for automatic feeding.

What are the technical specifications of BAT 115?

BAT 115 is a portable, battery tester for 6 V and 12 V starter batteries, including AGM, gel, and EFB batteries. It supports testing of 12/24 V starter systems for cars, boats, motorcycles, and light trucks. It features a printer for printing test results, multilingual interface, and compliance with standards like EN, DIN, SAE, IEC, JIS, and MCA.

How to perform a battery test?

Connect BAT 115 to the vehicle battery, select the battery type and standard, and choose the cold cranking amps (CCA). The device will then test the battery's capacity and display results including voltage, cold cranking ability, and internal resistance. It will also provide recommendations for charging or replacement.

What should I do if the display does not turn on?

Check the connection to the vehicle battery, verify the polarity, and ensure the battery voltage is above 1 V. If the battery is low, fully charge it and test again. If the issue persists, replace the internal batteries in BAT 115.

How to perform a system test?

Connect BAT 115 to the battery, select the system test, and start the engine. The device will evaluate the voltage drop during startup, voltage ripple without load, and voltage under load. Ensure all vehicle consumers are turned off before starting the engine, and use the tester to assess the alternator and charging system performance.

What does the 'GUT & LADEN' result mean?

The 'GUT & LADEN' result indicates the battery is in good condition but needs to be charged. It is recommended to charge the battery and retest to ensure accurate results. If the result appears even after a full charge, the battery may need to be replaced.

What should I do if the printer is not working?

Check if the thermal paper is properly loaded and the paper roll is correctly inserted. If no paper is present, replace the paper roll. Ensure the printer is connected and the device is powered on. If the issue persists, clean the printer rollers and check for any paper jams.

How to clean BAT 115?

Clean the housing and display of BAT 115 using soft cloths and neutral cleaning agents. Avoid using abrasive cleaners or rough workshop rags. Ensure the device is powered off and disconnected from any battery before cleaning.

What does the 'OBERFLÄCHENSPG.' message mean?

The 'OBERFLÄCHENSPG.' message indicates surface voltage, which is a chemical reaction between solid and liquid in the battery. It occurs when the battery is fully charged. Allow the battery to rest for about an hour or apply a load for 3–5 minutes before testing to ensure accurate results.