Bosch EFEP 67D (224 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the purpose of the EFEP 60H and EFEP 67D?
The EFEP 60H and EFEP 67D are injection nozzle testers used to perform various tests on diesel injection nozzles, including opening pressure, seat tightness, and spray pattern analysis.
What is the pressure range for the EFEP 60H?
The EFEP 60H operates within a pressure range of 0 to 40 MPa (0 to 400 bar), making it suitable for testing nozzles of sizes P, R, S, and T.
What is the pressure range for the EFEP 67D?
The EFEP 67D operates within a pressure range of 0 to 60 MPa (0 to 600 bar), making it suitable for testing nozzles of sizes T, U, V, and W.
What type of oil should be used for testing?
Only ISO 4113-compliant test oil or clean diesel fuel should be used for testing. These oils are non-explosive and safe for use with the equipment.
How should the nozzles be cleaned before testing?
Nozzles should be cleaned using an ultrasonic cleaner. The nozzle needle should be removed from the body and cleaned separately. After cleaning, the parts should be dried with compressed air and then immersed in clean test oil or diesel fuel.
What is the recommended temperature for test oil?
The test oil should be at a temperature of 23 ± 5 °C. This ensures accurate and reliable test results during the evaluation of the nozzle performance.
What is the procedure for checking the opening pressure?
To check the opening pressure, slowly increase the pressure using the hand lever until the pressure gauge stops moving. The highest pressure recorded at this point is the opening pressure. Adjustments can be made using the adjustment screw or washers if the pressure deviates from the specified value.
How is the seat tightness tested?
To test seat tightness, apply pressure until the pressure gauge shows 20 bar below the opening pressure. No droplets should fall from the nozzle tip within 10 seconds, indicating a proper seal.
What are the required conditions for the spray pattern test?
The spray pattern test requires the use of clean test oil or diesel fuel at 23 ± 5 °C. The pressure gauge must be fully depressurized before starting the test, and the nozzle should be inspected for any mechanical damage prior to testing.
What should be done if the pressure drop time is not within the acceptable range?
If the pressure drop time is not within the acceptable range, the nozzle assembly should be disassembled and cleaned. If the issue persists after cleaning, the nozzle and relevant parts of the nozzle holder should be replaced with new components.
Related products from Bosch
Vivalytic
User manual 8 pages
KTS 200
User manual 158 pages
KTS 340
User manual 32 pages
KTS 340
User manual 230 pages
BAT 121
User manual 20 pages
KDAS 0003
User manual 20 pages
DCU 130
User manual 22 pages
DCU 130
User manual 172 pages
FME-420-LSN-TTL
User manual 36 pages
T 12 200 E
User manual 36 pages
CRIN 848H
User manual 44 pages
CRIN 848H
User manual 380 pages
Denoxtronic 2.2
User manual 48 pages
Denoxtronic 2.2
User manual 464 pages
200 C
User manual 52 pages
200 C
User manual 385 pages
300 C
User manual 52 pages
BAT 131
User manual 116 pages
BAT 131
User manual 188 pages
BAT 250
User manual 124 pages