SICK G20 (156 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum allowable torque for installation?
The maximum allowable torque for installation is less than 0.55 Nm for certain connections and less than 0.3 Nm for others. Ensure the torque does not exceed these limits to avoid damaging the sensor or reflector.
How to connect the sensor electrically?
The sensor must be connected with the power supply disconnected. Follow the wiring instructions based on the connection type, including pin assignments, wire colors, and terminal connections. Ensure all connections are secure and correct before powering the device.
What are the electrical specifications for DC operation?
The sensor operates on DC voltage ranging from 10 to 30 V. The wiring must be appropriate for the current rating, with wire sizes ranging from 0.14 to 1.5 mm² for AWG26, and 0.14 to 0.5 mm² for AWG20 to 26. Use stranded wire for optimal performance.
What are the safety precautions for installation?
Ensure the sensor is not installed in areas exposed to direct UV radiation or weather conditions unless specified in the manual. Always protect the device from moisture and contamination during installation. Only trained personnel should handle the installation and configuration.
What is the UL approval rating for the device?
The device must be supplied from an isolating transformer with a secondary overcurrent protective device compliant with UL 248. The maximum current is 5 amps for voltages up to 20 V or 100/Vp for voltages between 20 V and 30 V. Alternatively, a Class 2 voltage supply can be used. The enclosure type is 1 for UL environmental rating.
What are the operating modes for the sensor?
The sensor has multiple operating modes, including light (L) and dark (D) settings, which can be adjusted using the potentiometer. The delay time can also be set to control the response time of the sensor for different applications.
How to align the sensor and reflector?
Mount the sensor and reflector on suitable mounting angles and align them precisely with each other. Ensure that the mounting torque does not exceed the specified limits to prevent damage and ensure accurate operation.
What are the terminal connection specifications?
The terminal connections include specific wire colors and pin assignments. For example, BN is brown, WH is white, BU is blue, BK is black, and n.c. indicates no connection. The digital output is marked as Q/Q, and the power supply is labeled as L+ while the ground is M. Follow these markings for correct wiring.
What is the purpose of the potentiometer on the sensor?
The potentiometer is used to adjust the sensitivity of the sensor, allowing for fine-tuning of the detection range. It can also be used to set the delay time, which controls the response time of the sensor to detected objects.
What are the recommended practices for maintenance?
Regularly inspect the sensor and reflector for signs of damage or wear. Ensure the mounting is secure and the connections are clean and free from corrosion. Avoid exposing the device to extreme temperatures or moisture, and follow the recommended maintenance schedule to ensure reliable operation.
Related products from SICK
W9-3
User manual 54 pages
W9-3
User manual 144 pages
LFP Inox
User manual 56 pages
WLA12L
User manual 212 pages
WE34
User manual 164 pages
WS34
User manual 131 pages
WS34
User manual 164 pages
WTF12L
User manual 232 pages
WTF12V
User manual 232 pages
WL34
User manual 164 pages
WT34
User manual 133 pages
GL6L
User manual 117 pages
GTB6L
User manual 160 pages
GTE6L
User manual 109 pages
GTE6L
User manual 130 pages
GTE6L
User manual 160 pages
GSE6L
User manual 119 pages
M4000 Standard
User manual 92 pages
LFH
User manual 48 pages
1049051
User manual 54 pages