Product description:
Frequently Asked Questions
How do I adjust the sensitivity of the GTE6L sensor?
The sensitivity of the GTE6L sensor is adjusted using the potentiometer. Rotate the potentiometer clockwise to increase the sensing range, and counterclockwise to decrease it. Ensure the object is within the sensing range during adjustment, and then remove the object from the beam path to observe the switching output change.
What is the laser class of the GTE6L sensor?
The GTE6L sensor operates with a laser class 1 laser, which is considered safe under normal conditions. It complies with EN/IEC 60825-1:2014 and IEC60825-1:2007 standards, with a maximum pulse power of < 5.95 mW, a pulse length of 2 µs, and a wavelength of 670-690 nm.
What are the electrical connection terminals for the GTE6L sensor?
The GTE6L sensor has the following connection terminals: BN (Brown), WH (White), BU (Blue), BK (Black), and n. c. (no connection). The terminals are used for power supply (L+), common (M), switching outputs (Q), and light/dark operate functions (L.ON, D.ON).
How do I align the GTE6L sensor with the object?
To align the GTE6L sensor, position it so that the red emitted light beam hits the center of the object. Ensure the optical opening (front screen) of the sensor is completely clear. Refer to figure 0 for guidance on proper alignment.
What is the sensing range of the GTE6L sensor?
The sensing range of the GTE6L sensor depends on the object's remission capability. For black objects (6% remission), gray objects (18% remission), and white objects (90% remission), the sensing range varies. Adjust the mounting position so that the sensing range and remission capability fall within the corresponding diagram.
What should I do if the yellow LED on the GTE6L sensor does not light up?
If the yellow LED does not light up, check the power supply and ensure all electrical connections are secure. Verify that the voltage is stable and within the required limits. If the power supply is correct, the sensor may be faulty and should be replaced.
What causes the yellow LED on the GTE6L sensor to flash?
A flashing yellow LED indicates that the sensor is still operational but the operating conditions are not ideal. Check the alignment of the light beam, clean the optical surfaces, and verify the sensing range. Adjust the settings if necessary.
What should I do if the yellow LED lights up but no object is in the beam path?
If the yellow LED lights up but no object is in the beam path, the background remission may be too high. Adjust the sensor's sensitivity or use a sensor with background suppression features. Ensure the background is not emitting excessive light.
How should I dispose of the GTE6L sensor?
The GTE6L sensor must be disposed of according to the applicable country-specific regulations. During disposal, efforts should be made to recycle the constituent materials, particularly precious metals, to minimize environmental impact.
Related products from SICK
W9-3
User manual 54 pages
W9-3
User manual 144 pages
WLA12L
User manual 212 pages
WE34
User manual 164 pages
WS34
User manual 131 pages
WS34
User manual 164 pages
WTF12L
User manual 232 pages
WTF12V
User manual 232 pages
WL34
User manual 164 pages
WT34
User manual 133 pages
GL6L
User manual 117 pages
GTB6L
User manual 160 pages
GSE6L
User manual 119 pages
M4000 Standard
User manual 92 pages
1049051
User manual 54 pages
1049053
User manual 54 pages
1049048
User manual 54 pages
1051889
User manual 54 pages
1049049
User manual 54 pages
GR18 Inox
User manual 97 pages