Product description:
Frequently Asked Questions
How to adjust the operating reserve of the GRSE18 sensor?
The operating reserve of the GRSE18 sensor can be adjusted using the potentiometer. Rotate the potentiometer clockwise to increase the operating reserve or counterclockwise to decrease it. It is recommended to set the potentiometer to 'Maximum' for optimal performance.
What is the recommended sensing range for the GRSE18 sensor?
The recommended sensing range for the GRSE18 sensor is 0 to 15 meters. This range ensures optimal performance and accurate detection of objects, animals, and persons.
How to mount the GRSE18 sensor?
Mount the GRSE18 sensor using suitable mounting brackets. Align the sender and receiver with each other, and ensure that the maximum permissible tightening torque is observed: 2.0 Nm for metal and 0.9 Nm for plastic.
What is the purpose of the test input on the GRSE18 sensor?
The test input on the GRSE18 sensor allows you to switch the sender off and check if the sensor is functioning correctly. Ensure that the test input is properly connected and that there are no objects between the sender and receiver when performing the test.
What should I do if the green LED on the GRSE18 sensor does not light up?
If the green LED does not light up, check the power supply and ensure that all electrical connections are secure. If the power supply is stable, the sensor may be faulty and should be replaced.
How to align the GRSE18 sensor for optimal performance?
Align the sender (GRS18) with the receiver (GRE18) so that the red emitted light beam hits the receiver. Use white paper or a reflector as an alignment aid. Ensure that the optical openings of the sensors are completely clear and that there are no objects in the path of the beam.
What are the technical specifications of the GRSE18 sensor?
The GRSE18 sensor has a sensing range of 0 to 15 meters, a light spot diameter of 250 mm at 10 meters, and operates on a DC supply voltage of 10 to 30 volts. The maximum output current is 100 mA, and the sensor is suitable for non-contact optical detection of objects, animals, and persons.
What should I do if the yellow LED on the GRSE18 sensor is flashing?
If the yellow LED is flashing, it indicates that the sensor is ready for operation but the operating conditions are not ideal. Fully align the light beam with the receiver, clean the optical surfaces, readjust the sensitivity using the potentiometer, and ensure there is sufficient distance between sensors.
How to ensure the GRSE18 sensor is not affected by interference from other sensors?
To prevent interference, swap the sender and receiver arrangement at every second through-beam photoelectric sensor and ensure there is sufficient distance between them. This helps avoid mutual interference and ensures accurate detection.
What should I do if the sensor fails to detect an object?
If the sensor fails to detect an object, check the application conditions, including the alignment of the sender and receiver, the distance between them, and the presence of any objects in the beam path. Ensure the sensor is properly configured and that the power supply is stable.
Related products from SICK
W9-3
User manual 54 pages
W9-3
User manual 144 pages
LFP Inox
User manual 116 pages
WTB4-3P2100S13
User manual 38 pages
WL12G-3P3572S12
User manual 48 pages
WLA12L
User manual 212 pages
WE34
User manual 164 pages
WS34
User manual 131 pages
WS34
User manual 164 pages
WTF12L
User manual 232 pages
WTF12V
User manual 232 pages
OLS20
User manual 4 pages
PowerProx - WTT12L
User manual 70 pages
PowerProx - WTT12L
User manual 93 pages
PowerProx - WTT12L
User manual 140 pages
PowerProx - WTT12L
User manual 164 pages
RAY10
User manual 144 pages
RAY10
User manual 166 pages
RAY10
User manual 184 pages
WL34
User manual 164 pages