What is the maximum permissible tightening torque for the sensor?
The maximum permissible tightening torque for the sensor is 0.56 Nm. Ensure that this limit is not exceeded during installation to avoid damage.
What are the laser safety classifications for the HTF18L sensor?
The HTF18L sensor is classified as LASERCLASS 1, complying with EN/IEC 60825-1:2014 and IEC60825-1:2007. It has a maximum pulse power of < 4.0 mW, a pulse length of 4 µs, and a wavelength range of 650 - 670 nm.
What are the electrical connection pinouts for the sensor?
The electrical connection pinouts include BN (Brown), WH (White), BU (Blue), BK (Black), n. c. (no connection), Q1 (switching output 1), Q2 (switching output 2), L+ (supply voltage), L1 (AC supply voltage), M (common), N (AC common), Test (Test input), L.ON (light switching), and D.ON (dark switching).
How should the sensor be mounted?
Mount the sensor using a suitable mounting bracket from the SICK range of accessories. Ensure that the maximum permissible tightening torque of 0.56 Nm is not exceeded during installation.
What are the DC output operation configurations for the sensor?
The DC output operation configurations vary based on the model configuration. For example, Q1 can be set to D.ON (dark on) or L.ON (light on), with PNP or NPN outputs, depending on the model designation such as HTX18-xxxxx.
What are the electrical installation requirements for the sensor?
The sensors must be connected in a voltage-free state (UV = 0 V). Ensure all electrical connections are made before applying voltage. The green LED on the sensor indicates that the supply voltage is active.
What are the safety notes for operating the sensor?
Read the operating instructions before commissioning. Ensure the device is protected from moisture and contamination during installation. Avoid interruption, manipulation, or incorrect use to prevent hazardous laser exposure.
What is the intended use of the HTF18 sensor?
The HTF18 is an opto-electronic photoelectric proximity sensor for the optical, non-contact detection of objects, animals, and persons. It is not intended for any other use, and using it for other purposes voids the warranty.
What are the technical specifications for the HTF18 sensor?
The HTF18 sensor is a hybrid photoelectric sensor with foreground suppression. It complies with 21 CFR 1040.10 and 1040.11, except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. It is designed for non-contact detection of objects.
What are the connection pinouts for the HTF18 sensor?
The connection pinouts include Brown (BN), White (WH), Blue (BU), Black (BK), no connection (n. c.), switching outputs Q1 and Q2, supply voltage (L+), AC supply voltage (L1), common (M), AC common (N), Test input, light switching (L.ON), and dark switching (D.ON).
Related products from SICK
W9-3
User manual 54 pages
W9-3
User manual 144 pages
LFP Inox
User manual 56 pages
WLA12L
User manual 212 pages
WE34
User manual 164 pages
WS34
User manual 131 pages
WS34
User manual 164 pages
WTF12L
User manual 232 pages
WTF12V
User manual 232 pages
WL34
User manual 164 pages
WT34
User manual 133 pages
GL6L
User manual 117 pages
GTB6L
User manual 160 pages
GTE6L
User manual 109 pages
GTE6L
User manual 130 pages
GTE6L
User manual 160 pages
GSE6L
User manual 119 pages
M4000 Standard
User manual 92 pages
LFH
User manual 48 pages
1049051
User manual 54 pages