Product description:
Frequently Asked Questions
How do I ensure my gauge has the latest firmware?
To ensure your gauge has the latest firmware, connect it to ElcoMaster® on a regular basis. Use the 'Connect Gauge' feature on an internet-connected computer. If an update is available, click 'Update Gauge' to install the latest firmware.
How do I fit or replace a probe tip?
To fit or replace a probe tip, first unscrew the probe tip collar from the probe body. Remove the worn or damaged tip, then slide a new tip into the collar. Apply a small drop of probe tip oil to the sensor plate and refit the collar. Always check for wear or damage before use.
How do I oil the sensor plate?
To oil the sensor plate, unscrew the probe tip collar and remove the probe tip. Apply a small drop of probe tip oil to the sensor plate. Refit the probe tip and collar, ensuring there is no air gap between the tip and sensor plate for accurate readings.
How do I take a reading in standard mode?
To take a reading in standard mode, apply a small amount of couplant to the surface. Press the probe into the couplant, ensuring it is flat against the surface. The display will show a constantly updating value. A green signal strength indicator means a valid and stable reading.
How do I take a reading in scan mode?
To take a reading in scan mode, enable it via Menu/Setup/Reading/Scan Mode. Apply couplant to the surface and press the probe flat against it. Slide the probe across the surface to collect data. The display will show the average, lowest, and highest readings, which can be saved or cleared.
What should I do if the signal strength indicator is not green?
If the signal strength indicator is not green, ensure there is an adequate film of couplant beneath the probe and that the probe is seated flat against the surface. If the issue persists, reposition the probe on a different area of the test surface until a strong signal is received.
How do I check the performance of the gauge and probe?
To check the performance of the gauge and probe, use the measurement foils supplied with each probe. Select the appropriate foil from the 'Generic Materials' list in the calibration menu, apply couplant, and take a reading to verify accuracy.
What should I do if the probe tip is worn or damaged?
If the probe tip is worn or damaged, the gauge will prompt you to replace it. If the wear is greater than 0.7mm but less than 1mm, you can choose to continue with the current tip or replace it. If the wear is greater than 1mm, you must replace the tip to maintain accuracy.
How do I switch the gauge on or off?
To switch the gauge on, press the on/off key for more than 0.5 seconds. To switch it off, press and hold the on/off key until the screen goes blank. The gauge can also be set to auto-off after a user-defined period of inactivity via the menu settings.
What should I do if the battery indicator shows low power?
If the battery indicator shows low power, replace the batteries immediately. The battery condition is indicated by a symbol in the top right of the display. A red, flashing symbol means the batteries are at their lowest sustainable level. Dispose of used batteries carefully to avoid environmental contamination.
Related products from Elcometer
415
User manual 112 pages
P500
User manual 16 pages
107
User manual 84 pages
1506-B
User manual 24 pages
138
User manual 32 pages
138
User manual 32 pages
138
User manual 48 pages
103
User manual 28 pages
456
User manual 28 pages
456
User manual 72 pages
456
User manual 72 pages
456
User manual 112 pages
456
User manual 112 pages
102
User manual 28 pages
116C
User manual 33 pages
224
User manual 70 pages
1510
User manual 57 pages
2352
User manual 60 pages
2351
User manual 60 pages
2350
User manual 60 pages